33
Personnel.
46# Follow-On Mode & Two way Period:
-
This is used to program the allowable time duration for Follow-On mode choice (Commend
#45) & Two-way voice communication period (Speech mode). It can be set from 1 to 10
minutes.
47# Off-Set Time:
-
After power is supplied or re-supplied to the Control Panel, the first auto check-in report will be
made according to Offset Period setting. This is used to test whether the CMS is able to
receive the report from the Panel accurately.
-
After this test report is sent, the Control Panel will then send reports at regular interval based
on the setting of the
Periodic Test Call
.
49# Supervision:
-
This option is used to enable system Supervision function. Once enabled, CTC-1052-QT will be
able to receive the check-in signals from Wrist Pendants (WTR) to indicate their proper
functioning.
-
When the supervisory timer expires and no supervision signal is received from WTR, CTC-
1052-QT will send a Supervisory Failure report.
53# Voice Prompt Language:
-
Select the voice prompt language for CTC-1052-QT. Available options include English, French,
Spanish and Beep_only.
63# Set Speaker Volume:
-
Select the speaker volume level. 5 is the maximum level, while 1 is the minimum level.
64# Microphone Sensitivity:
-
Select the microphone sensitivity level. 5 is the highest sensitivity level, while 1 is the lowest
sensitivity level.
66# Guard Time Delay for Fall Sensor:
-
The Guard Time for Fall Sensor‟s fall detection function is set separately from regular Guard
Time.
-
CTC-1052-QT can be programmed to delay alarm reporting (triggered by Fall detection) from
(
00
) (instant reporting) to (
99
) seconds.
-
During this period, a continuous series of beeps will be emitted to alert user. If a false alarm is
triggered by
Fall Sensor
, it can be cancelled within the Guard Time Delay.
-
If an emergency alarm is triggered by pressing the Active Button on Fall Sensor, the guard time
delay time is determined by Command #42 Guard Time Delay, instead of Command #66
Guard Time Delay Time for Fall Sensor.
67# Setting the Help Arrived Timer:
-
This is used to set the countdown timer for CTC-1052-QT to resend the alarm report if no help
has arrived after the initial report is made (meaning the reset button has not been pressed
before the timer expires).
-
The Help Arrived function (Command
33
) must be set as
ON
for this function to work.
75# Help Not Arrived Call:
-
If help has not arrived after sending the alarm report for 4 times, CTC-1052-QT will dial the