background image

WWW.CLF-LIGHTING.COM

21

Color Macro Chart

DMX value

Gel Name

Color Number

DMX value

Gel Name

Color Number

0-4

no function

 

44

Fern Green

LEE 122 

5

Rose Pink

LEE 002 

45

Dark Green

LEE 124 

6

Medium Bastard Amber

LEE 004 

46

Mauve

LEE 126 

7

Pale Yellow

LEE 007 

47

Smokey Pink

LEE 127 

8

Dark Salmon

LEE 008 

48

Bright Pink

LEE 128 

9

Pale Amber Gold

LEE 009 

49

Marine Blue

LEE 131 

10

Medium Yellow

LEE 010

50

Medium Blue

LEE 132 

11

Straw Tint

LEE 013

51

Golden Amber

LEE 134 

12

Deep Straw

LEE 015 

52

Deep Golden Amber

LEE 135 

13

Surprise Peach

LEE 017 

53

Special Lavender

LEE 137 

14

Medium Amber

LEE 020 

54

Pale Green

LEE 138 

15

Dark Amber

LEE 022 

55

Primary Green

LEE 139 

16

Sunset Red

LEE 025 

56

Summer Blue

LEE 140 

17

Bright Red

LEE 026 

57

Bright Blue

LEE 141 

18

Medium Pink

LEE 036 

58

Pale Violet

LEE 142 

19

Rose Purple

LEE 048 

59

Pale Navy Blue

LEE 143 

20

Lavender

LEE 058 

60

No Colour Blue

LEE 144 

21

Pale Blue

LEE 063 

61

Apricot

LEE 147 

22

Sky Blue

LEE 068 

62

Bright Rose

LEE 148

23

Tokyo Blue

LEE 071

63

Gold Tint

LEE 151 

24

Evening Blue

LEE 075 

64

Pale Gold

LEE 152 

25

Lime Green

LEE 088

65

Pale Salmon

LEE 153 

26

Moss Green

LEE 089 

66

Pale Rose

LEE 154 

27

Dark Yellow Green

LEE 090 

67

Chocolate

LEE 156 

28

Yellow

LEE 101 

68

Pink

LEE 157 

29

Straw

LEE 103

69

Deep Orange

LEE 158 

30

Deep Amber

LEE 104

70

Slate Blue

LEE 161 

31

Orange

LEE 105 

71

Bastard Amber

LEE 162 

32

Primary Red

LEE 106 

72

Flame Red

LEE 164 

33

Light Rose

LEE 107 

73

Daylight Blue

LEE 165 

34

English Rose

LEE 108

74

Deep Lavender

LEE 170 

35

Light Salmon

LEE 109 

75

Lagoon Blue

LEE 172 

36

Middle Rose

LEE 110 

76

Dark Steel Blue

LEE 174 

37

Dark Pink

LEE 111 

77

Loving Amber

LEE 176 

38

Magenta

LEE 113 

78

Chrome Orange

LEE 179 

39

Peacock Blue

LEE 115 

79

Dark Lavender

LEE 180 

40

Steel Blue

LEE 117 

80

Congo Blue

LEE 181 

41

Light Blue

LEE 118 

81

 Moonlight Blue

LEE 183 

42

Dark Blue

LEE 119 

82

 Flesh Pink

LEE 192 

43

LEE Green

LEE 121 

83

Surprise Pink

LEE 194 

Summary of Contents for POSEIDON WASH XS

Page 1: ...manual WWW CLF LIGHTING COM V2 0 MAY 2022 POSEIDON wash xs ...

Page 2: ... fixture to a flat surface 7 Rigging via omega bracket 8 Outdoor IP rated fixtures 9 Condensation moisture inside housing 9 Fixtures temperature specification 9 Setup 10 Control panel and menu navigation 10 DMX address setting 10 W DMX control optional q1 2019 10 Control mode 11 Control panel 12 Onboard control menus 14 DMX protocols 16 Arrangement of the LED groups 1 7 18 Static pixel effect char...

Page 3: ...Dimensions All dimensions are in millimeters WWW CLF LIGHTING COM 1 106 106 202 467 300 ...

Page 4: ... please contact your supplier PROTECTION FROM ELECTRIC SHOCK Disconnect the fixture from AC power before removing or installing any cover or part and when not in use Always ground earth the fixture electrically Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault earth fault protection Before using the fixture check that all po...

Page 5: ...g lamp Eye injury may result Do not look at the light output with magnifiers telescopes binoculars or similar optical instruments that may concentratethe light output Ensure that persons are not looking directly into the front of the fixture when the product lights up suddenly This can happen when power is applied when the product receives a DMX signal or when certain control menu items are select...

Page 6: ...WWW CLF LIGHTING COM 4 Fixture overview LCD Display AC mains power input output Control buttons WDMX 5P DMX input 3P DMX input accessoires CLF 13 453 5P DMX output 3P DMX output accessoires CLF 13 454 ...

Page 7: ...tion Warning Socket outlets or external power switches used to supply the fixture with power must be located near the fixture and easily accessible so that the fixtures can easily be disconnected from power Important Do not insert or remove PowerCON TRUE 1 connectors to apply or cut power as this may cause arcing at the terminals that will damage the connectors Important Do not use an external dim...

Page 8: ...onnect the DMX output of the fixture closest to the controller to the DMX input of the next fixture and continue connecting fixtures output to input Relaying power to other devices Warning Do not connect more than seven fixtures in total to AC mains power in one interconnected chain Power can be relayed to another device via the PowerCON TRUE 1 throughput socket If you daisy chain the fixtures in ...

Page 9: ...ight of the fixture using one of the attachment points at the edges of the base see Fixture overview Do not use any other part of the fixture as a safety cable attachment point The installation of the fixture has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation The installation must always be secured with a secondary safety attach...

Page 10: ... distance of min 0 5 m Use an appropriate clamp to rig the fixture on the truss Follow the instructions mentioned at the bottom of the base Make sure that the device is fixed properly Ensure that the structure truss to which you are attaching the fixtures is secure The fixture can be placed directly on the stage floor or rigged on a truss without altering its operation characteristics For securing...

Page 11: ...n mind that it can bring damage to aging materials and affect the coated surface i e stainless steel Rubber sealings will be negatively affected after long term UV exposure and should be checked by qualified service technicians over time Tighten screws too hard will also affect the IP rating solid object Moisture 1 2 3 4 5 6 7 8 IP Ingress Protection 6 5 Protected against a solid object greater th...

Page 12: ...redas by using the DMX ADDRESS menu in the control panel For setting the DMX address press ENTER before you can change the address The main screen will show a dot and the backlight will be switched off when a DMX signal is detected The fixture is fully RDM ready So when you are using a RDM ready console you can address the unit and read out its complete status For RDM functions please refer to the...

Page 13: ...with 3 DMX control modes Small 20CH Medium 27CH Large 55CH Shutter Dimmer Dimmer fine Pan Pan fine Tilt Tilt fine P T speed time Zoom Function set Macro color RGBL RGBL fine LED 1 7 RGBL CCT CCT channel tint Static pixel effect Move pixel effect Move pixel effect speed Crossfade dimmer Back ground color Back ground dimmer ...

Page 14: ... The fixture will remember on last values when you disconnect DMX NO DMX HOLD The fixture has no output when you disconnect DMX Display Rotate Auto Normal Background Light always on Auto off BL blinking when no DMX Yes NO Auto Display Flip Function enabled Auto Display Flip Function disbaled Display background Light always on Display deactivation after approximately 15 second of inactivity When th...

Page 15: ...rser at medium levels Special the light intensity was linear increase with DMX value and light intensity control is finer at low level with DMX values decrease the dimmer speed will also has effect on it Whichever DIMMER CURVE option you select you can choose between NORMAL or SMOOTH 1 2 3 4 dimming settings NORMAL is the default setting It gives a virtually instantaneous reaction when you dim fro...

Page 16: ...Red 3 29 Green 3 30 Blue 3 31 Lime 3 32 Red 4 33 Green 4 34 Blue 4 35 Lime 4 36 Red 5 37 Green 5 38 Blue 5 39 Lime 5 40 Red 6 41 Green 6 42 Blue 6 43 Lime 6 44 Red 7 45 Green 7 46 Blue 7 47 Lime 7 48 CCT 49 CCT channel tint 50 Static pixel effect 51 M P effect 52 M P effect speed 53 Crossfade dimmer 54 BG color 55 BG dimmer 3 Motor Pan invert Normal Inverted Default Normal Tilt invert Normal Inver...

Page 17: ...ult 000 Pan 0 255 Default 000 Pan fine 0 255 Default 000 Tilt 0 255 Default 000 Tilt fine 0 255 Default 000 Zoom 0 255 Default 000 7 Test Test led Test pan Test tilt Test zoom Test all 8 INFO Software version Display board Vx xx Pan Tilt board Vx xx Led board Vx xx Usage time TOTAL Xxxx H LED total Xxxx H Temperature Head XXX C Stored max XXX C Stored min XXX C Base XXX C Stored max XXX C Stored m...

Page 18: ...tter open 150 164 Strobe 6 random closing pulse fast slow 165 169 Shutter open 170 184 Strobe 7 burst pulse fast slow 185 189 Shutter open 190 204 Strobe 8 random burst pulse fast slow 205 209 Shutter open 210 224 Strobe 9 sine wave fast slow 225 229 Shutter open 230 244 Strobe 10 burst fast slow 245 255 Shutter open 2 2 2 Dimmer 000 255 0 100 3 3 Dimmer fine 000 255 0 100 3 4 4 Pan 000 255 Pan mo...

Page 19: ...rmal 190 194 No function 195 199 Dimmer Speed Smooth 1 200 204 Dimmer Speed Smooth 2 205 209 Dimmer Speed Smooth 3 210 214 Dimmer Speed Smooth 4 215 219 No function 230 234 Pan tilt motor reset 235 239 No function 240 244 Zoom motor reset 245 249 No function 250 255 Illuminate display 10 11 11 Color macro 000 255 Please see page 21 Color macro chart 11 12 12 Red 000 255 0 100 13 13 Red fine 000 25...

Page 20: ...ction 006 255 10000k 2500k 21 49 CCT channel tint 000 No Function 001 127 Magenta Neutral 128 128 Neutral 129 255 Neutral Green 15 22 50 Static pixel effect 000 255 Please see page 19 Static effect 16 23 51 Moving pixel effect 000 255 Please see page 20 Moving effect 17 24 52 Moving effect speed 000 255 Slow Fast 18 25 53 Crossfade dimmer 000 255 Fast Slow 19 26 54 Background color 000 255 Please ...

Page 21: ...49 35 175 179 10 050 054 36 180 184 11 055 059 37 185 189 12 060 064 38 190 194 13 065 069 39 195 199 14 070 074 40 200 204 15 075 079 41 205 209 16 080 084 42 210 214 17 085 089 43 215 219 18 090 094 44 220 224 19 095 099 45 225 229 20 100 104 46 230 234 21 105 109 47 235 239 22 110 114 48 240 244 23 115 119 49 245 249 24 120 124 50 250 254 25 125 129 51 255 Background color White control by Back...

Page 22: ...lue Pixel Dmx Value step 1 step 2 step 3 step 4 step 5 step 6 step 7 step 8 step 9 step10 step11 step12 0 000 004 No funtion 1 005 009 2 010 014 3 015 019 4 020 024 5 025 029 6 030 034 7 035 039 8 040 044 9 045 049 10 050 054 11 055 059 12 060 064 13 065 069 14 070 074 15 075 079 16 080 084 17 085 089 18 090 094 19 095 099 20 100 104 21 105 109 22 110 114 23 115 119 24 120 255 ...

Page 23: ...r LEE 058 60 No Colour Blue LEE 144 21 Pale Blue LEE 063 61 Apricot LEE 147 22 Sky Blue LEE 068 62 Bright Rose LEE 148 23 Tokyo Blue LEE 071 63 Gold Tint LEE 151 24 Evening Blue LEE 075 64 Pale Gold LEE 152 25 Lime Green LEE 088 65 Pale Salmon LEE 153 26 Moss Green LEE 089 66 Pale Rose LEE 154 27 Dark Yellow Green LEE 090 67 Chocolate LEE 156 28 Yellow LEE 101 68 Pink LEE 157 29 Straw LEE 103 69 D...

Page 24: ...LEE 508 102 Super Correction W F Green LEE 232 142 Argent Blue LEE 525 103 HMI to Tungsten LEE 236 143 ALD Gold LEE 550 104 CID to Tungsten LEE 237 144 Full CT Eight Five LEE 604 105 CSI to Tungsten LEE 238 145 Industry Sodium LEE 650 106 LEE Fluorescent 5700 Kelvin LEE 241 146 HI Sodium LEE 651 107 LEE Fluorescent 4300 Kelvin LEE 242 147 Urban Sodium LEE 652 108 LEE Fluorescent 3600 Kelvin LEE 24...

Page 25: ... 738 173 Bram Brown LEE 742 174 Dirty White LEE 744 175 Easy White LEE 747 176 Seedy Pink LEE 748 177 Wheat LEE 763 178 Sun Colour Straw LEE 764 179 LEE Yellow LEE 765 180 Oklahoma Yellow LEE 767 181 Egg Yolk Yellow LEE 768 182 Burnt Yellow LEE 770 183 Rust LEE 777 184 Millennium Gold LEE 778 185 Bastard Pink LEE 779 186 AS Golden Amber LEE 780 187 Terry Red LEE 781 188 Moroccan Pink LEE 790 189 V...

Page 26: ...e Normal mode beam angle 4 29 8 Beam angle 50 Normal mode beam angle 4 37 6 Field angle 10 Wide mode beam angle 4 39 6 Beam angle 50 Wide mode beam angle 4 58 8 Field angle 10 Photometric Output 1M 295602 lux Output 5M 11824 lux Heat management Cooling type Passive cooling MAX Ambient temp Ta max 40 C MIN Ambient temp Ta min 25 C MAX housing temp ta 25 C 50 C MAX housing temp ta 40 C 65 C Menu Aut...

Page 27: ... with optional chassis part Data input artnet SACN None Hardware Interface Backlite LCD display Software upload method XLR via special box Installation IP rating IP65 Housing Safety attachment point Yes Physical Net product weight 12 7 kg Machine dimensions Length 300 mm Machine dimensions Width 205 mm Machine dimensions Height 467 mm Accessories Included items Power cable manual Approvals Approve...

Page 28: ...WWW CLF LIGHTING COM CLFLIGHTING POSEIDON wash xs ...

Reviews: