PULSAR
®
III-P/III-PE and VI-P/VI-PE PRESSURE CABINETS
Page 9
© 2019 CLEMCO INDUSTRIES CORP.
www.clemcoindustries.com
Manual No. 21527, Rev. I, 02/19
2.6.2
Position the foot pedal on the floor at the front of
the cabinet or on the foot shelf on ergonomic models.
2.6.3
A package of five cover lenses is supplied with the
cabinet. To install a cover lens, remove the adhesive
backing and apply the lens to the clean, dry, inner surface
of the view window. Refer to Section 7.4. When the cover
lens becomes pitted or frosted, replace it.
3.0
FIELD INSTALLED ACCESSORIES
3.1
Aluminum Oxide (aggressive media) Kit
3.1.1
An optional aluminum oxide kit is available
factory installed or may be field installed later.
Factory-installed kits consist of black-rubber cabinet
curtains with grommets, curtain hardware, and a boron
carbide nozzle.
Field-installed (or replacement factory installed) kits
consist of black-rubber cabinet curtains (refer to Section
3.2 for curtain installation) a boron carbide nozzle, and
light-lined flex hose. If the existing flex hose is in good
condition, reserve the new hose for future replacement.
3.2
Cabinet Curtains Installation
3.2.1
Match curtains to corresponding walls and door.
3.2.2 Front and rear walls:
Position the curtain on
the wall to be protected. Using the curtains as templates,
mark each mounting point through the grommet holes
along the upper edge of the curtain. NOTE: When laying
out the attachment points, the upper edge of the rear
curtain should be below the bottom edge of the air-duct
partition. Remove the curtains and drill a .187" (3/16")
diameter hole at each point marked. Install the curtains
using the fasteners provided (machine screw, 11/16
OD
flat washer, lock washer and nut) at each grommet. The
flat washer is used between the screw head and the
rubber curtain grommet on all curtains.
3.2.3
Doors:
Use protectors against the curtains and
outer doors; clamp the door curtains in place. NOTE:
When laying out the attachment points, the upper edges
of the door curtains should be even with the outer edges
of the door’s soundproofing panel. Insert a #10 self-
drilling screw with an 11/16" OD flat washer through the
grommet holes. Use a screw gun with a 5/16" socket to
drill and thread the screws through the door’s inner wall
at each grommet.
3.2.4 Ergo side extensions:
Position the curtain on
the wall to be protected. Use the curtain as a template
and mark the top mounting point through the grommet.
Remove the curtain and drill a .187" (3/16") diameter
hole at each point marked. Install the curtains using the
fasteners provided (machine screw, 11/16
OD flat
washer, lock washer and nut) at each grommet. The flat
washer is used between the screw head and the rubber
curtain grommet on all curtains. After hanging the
curtain, mark and drill the cabinet and attach the lower
grommets in like manner.
3.3
Manometer
The optional manometer kit is listed in
Section 9.1
:
Optional Accessories
.
3.3.1
Consistent static pressure is necessary for
precise media separation, as the reclaimer's efficiency is
achieved by a centrifugal balance of air flow, particle
weight, and size. The manometer measures static
pressure. Reclaimer static pressure is set by adjusting the
dust-collector damper. Refer to Section 5.3 to adjust static
pressure. Refer to Section 5.7 for manometer instructions.
3.4
Reclaimer Differential-Pressure Gauge
Monitors reclaimer static pressure ‒ Figure 8
3.4.1
The reclaimer differential pressure gauge
continually measures reclaimer static pressure, similar
to a manometer slack tube but it uses a differential
pressure gauge.
3.4.2
The gauge panel, gauge, filter, and panel fittings
come fully assembled; the bushings, snubber fittings, and
tubing are loose. Mount the panel at a location where it
can be easily monitored. A 10-foot length of tubing is
included with the kit, allowing the panel to be mounted
within 10 feet of the connections. One suggestion is to
mount it on an accessible side of the power module.
3.4.3
Mounting holes are on the left and right sides of
the gauge panel. After selecting the location, match drill
holes and use nuts and cap screws to secure the panel.
Figure 8
3.4.4
Remove the 1/4" pipe plug from the reclaimer
body and install 1/4" x 1/8" bushing and barb fitting, as
shown in Figure 8.
Urethane Tubing
Differential
Pressure Gauge
Remove plug and install
bushing and barb fitting.