Fault location and suggested remedies.

 

Fault 

Possible cause 

Recommended activity 

Blocked filter / low airflow  Filter not cleaned frequently 

enough 

 
 

No cleaning on filter “clean” 

operation 

 
 
 
 
 

Filter bags are saturated with 
fine dust 

  Cleaning cycle after stop: Stop 

the filter more frequently  

  / check that cleaning does in 

fact take place 

  Check that the emergency stop 

is not activated on normal stop / 
check that the electrical 
connection is correct so that the 
cleaning  operates 

 
 

  Clean / replace the filter bags 

Material accumulates in 
filter bottom 

Blocked emptying system, if 
other than bin 
 
 
 
 
 
Wet waste sticks to the walls 
 
 
 

  Air circulation in filter bottom 

prevents the waste from 
being transported to the 
outlet opening 

  Check, possibly that the 

emptying system works 
correctly 

  Check that the dust collection 

bin is not full 

 

  Seal filter housing 

  Insulate the filter and hopper 

against condensation 

  Reduce water content of waste 

  Fit pre-separation section after 

seeking advice from technician 

The sacks or quick 
release bins are not 
equally filled 

  Natural phenomenon which 

depends on the composition 
of the waste 

  Accept this condition 

The filter doors are 
leaking or are blown open 

The door is not closed 
correctly 
Internal operating pressure is 
higher than specified 
(positive pressure operation) 

  Close the door correctly 

  Lower the operating pressure or  

reinforce filter and access door 

The filtered air contains 
dust 

Damaged filter bag(s) 
The filter bag(s) are not fitted 
or sealed correctly 
Wrong filter material  
The waste container is 
intended for use with a 
plastic liner but no plastic 
liner is used 
 

  Replace defective filter bag 

  Mount the filter bag(s) correctly 

 

  Contact technician 

  Use a plastic bag or disconnect 

and seal the connection for the 
bin balancing pipe 

 

 

 

Summary of Contents for Enviraclean Systems M Z 15

Page 1: ...e Clemco Ltd Auto MZ Filter Units Owners Manual TSOM 535 Date of Issue 13 07 04 Hodge Clemco Ltd Orgreave Drive Sheffield South Yorkshire S13 9NR Tel 0114 254 0600 Fax 0114 2540250 Email sales hodgecl...

Page 2: ...contained mechanically cleaned dust filter collector units It is designed to extract dust laden air from non continuous processes that is so that the fan can be temporarily stopped from time to time t...

Page 3: ...etween the filter body and hopper Smaller units may be manufactured and shipped as a single complete unit Unit assembly If the unit is supplied in one piece then transport upright and lift as shown be...

Page 4: ...sealant to the hopper top flange then position the filter top section complete with fan but with the silencer removed using a crane or forklift truck Refer to the diagram above for sling angles etc I...

Page 5: ...aker should then run for approximately 8 seconds Normal operation 1 Check that dustbins are not overfilled They would normally be emptied at the end of each operating period when the automatic after c...

Page 6: ...ler should be cleaned and the source of the dust leakage investigated Do not allow persistent vibration as damage will result Fan and shaker motors These motors are maintenance free For special motors...

Page 7: ...aps and dampers for operation and wear 6 1000 13 Check filter housing and hopper for leakage and wear 6 1000 14 Clean exterior of controller with a moist cloth 1 300 15 Check tightness of flange conne...

Page 8: ...2 Remove the nuts and washers from the lower bag mounting frame 3 Lift the mounting frame complete with the filter bag from the studs 4 Lift the frame and filter bag carefully out of the filter unit...

Page 9: ...ely without rubbing against anything Any defects must be corrected before the fan is put into use again Replacement of internally mounted shaker motor Removal 1 Isolate the electrical supply 2 Open fr...

Page 10: ...m works correctly Check that the dust collection bin is not full Seal filter housing Insulate the filter and hopper against condensation Reduce water content of waste Fit pre separation section after...

Page 11: ...replace inlet fitting The cleaning is not effective Filter bag blinded Shaker running slow Clean manually or replace bag Check mechanism of shaker Re location or disposal of units Safety note Stop an...

Page 12: ...the airflow volume reduces noticeably Typically this should allow at least 4 hours continuous running Operating temperature Auto M Z Series Standard Unit Gas temperature 80 C maximum 10 C minimum Ambi...

Page 13: ...nit type and serial number Electrical Controller See separate instructions supplied with controller NF Fan When ordering spare parts please state motor size in kW and the serial number of the filter T...

Page 14: ...Page 14 of 17 TS OM535 Date of Issue 13 07 04 Hodge Clemco Ltd...

Page 15: ...ombined graphically in VDI 3673 by nomographs which are then used to determine the area of the ventilation panels Unit located outdoors Unless it is technically impossible this is the preferred locati...

Page 16: ...ressure wave from the primary explosion dislodging dust from walls beams and other surfaces The result of such a secondary explosion could be catastrophic General recommendation It is always recommend...

Page 17: ...Page 17 of 17 TS OM535 Date of Issue 13 07 04 Hodge Clemco Ltd...

Reviews: