Page 12 of 17
TS OM535 Date of Issue: 13.07.04 Hodge Clemco Ltd
Max. positive pressure: + 500 Pa (50mm water) in clean air chamber
Max. negative pressure: - 5000 Pa (500mm water)
The normal operating differential pressure across the filter material depends upon the
load, dust type and concentration. It will normally be less than 1500 Pa (150mm water).
Maximum continuous running time
. This will depend upon the quantity and type of dust.
Stop and clean when either the bin is full or the airflow volume reduces noticeably.
Typically this should allow at least 4 hours-continuous running.
Operating temperature
: Auto M Z-Series
Standard Unit Gas temperature
80ºC maximum -10ºC minimum
Ambient temperature
40ºC maximum -10ºC minimum
Higher operating temperatures may be possible with specially modified units.
SPARE PARTS LIST. Auto M Z-Series and integral NF Fan.
Please state unit type and serial number when ordering spare parts. This data can be
found on the type plate of the filter.
Auto M Z-Series components: -
1
Access door
2
Sealing for side access door
3
Lock for access door, (not shown)
4
Hinge for access door, (not shown)
5
Filter bag
6
Bag sealing gasket