1 Scope of Manual
This manual covers setup, operation, maintenance, replacement parts, and important warnings for safe
operation of the Clemco Apollo 600 CE Supplied-Air Respirator.
Read the entire manual before installing or operating the equipment.
The following additional equipments may be used in conjunction with the Apollo 600 CE Respirator:
Part no.
Titel / Description
Remarks
03580 D resp.
03527 D
Air filter CPF-20 or CPF-80
Installation between air supply and air supply hose
23825D
Clem Cool air conditioner
In place of the air control valve to the air conditioning
04411I
Climate control
In place of the air control valve
–optionally for heat-
ing or cooling the air
25189D
DLX padded suspension kit
Supplementary mounted in the Apollo 600, for a bet-
ter more convenient fit.
24310D
Leather cape for Apollo 600
In place of the nylon capes (example during heavy
abrasive recoil)
24405D
Rubber Cape 4436
Instead of the nylon cape when a very intense recoil
of abrasive appears. Lighter than the leather cape.
24406D
ASS-Cape 4436 RA
Instead of the nylon cape to allow rope access.
Heavy duty rubber front.
2 Applications and limitations
2.1 General Description
The Apollo 600 CE was specially developed and approved for blasting. (MSHA - NIOSH and EN 271)
The following Cautions and Limitations have to be followed:
-
The supplied air has to be in accordance with the EN 12021.
- The Apollo 600 CE is
not suitable for any other work such as welding or painting!
- Only for the use in atmospheres which do not represent any imminent danger for life and health and
which contains a minimum oxygen volume of 19,5%.
- It is not allowed to use this product with pure oxygen or with oxygen enriched air.
- Not for the use in flammable atmospheres.
-
The Apollo 600 CE protects the wearer’s head and neck from impact and abrasion caused by rebound-
ing abrasive.
- The helmet is suitable for the usual vertical or a bit slopy posture of the head. In forced postures like
the horizontal posture when lying, the air indicator will not work.
- The helmet can be used at temperatures as follows:
o
Working:
-6° to +40°C.
o
Shipping and transition
-20° to +50°C
o
Stocking :
0 to +30°C.
- If the product is used under a temperature of 4°C the water content has to be reduced to avoid freezing
of the product.
- The supplied air must have a pressure between 6 and 8bar. To assure this pressure you can use our
Air Filter CPF 20 which has an integrated pressure regulator (Part No: 03580 D). See also 5.2.