MAINTENANCE
Tennant T500 (01-2017)
45
4. Carefully peel back the charger display label to
access the dial settings (Figure 125).
FIG. 125
5. Using a small standard screwdriver, turn the dial to
the appropriate battery type according to the
following chart (Figure 126).
FIG. 126
Dial
Position
Battery Description Settings
with AH Ranges
0
CAN-BUS setting*
1
Wet, Trojan 180-260 AH
2
Wet, Trojan 270-360 AH
3
Wet, Enersys/Tab 200-350 AH
4
AGM, Tianneng 180-260 AH
5
AGM, Discover 200-350 AH
6
Gel, Sonnenschein 80-150 AH
* The CAN-BUS setting, dial position “0”, is the
software setting that is programmed to match battery
type supplied with machine. When the dial is manually
changed to a different setting, it should not be reset
back to “0” otherwise battery damage may result.
Service Application Software is required to reset dial
back to “0”. Contact Service.
6. Re-apply the display label.
7. Replace the control console.
8. To set the BDI for the new battery type, plug the
on-board battery charger cord into an electrical
outlet. The machine's software will automatically
reprogram the BDI to the new battery type.
CHANGING ON-BOARD BATTERY CHARGER
SETTINGS (Pro-Panel model)
NOTE: To perform this procedure, machine must be in
supervisor mode.
See SUPERVISOR CONTROLS
instructions at back of manual.
1. Turn the key to the on position.
2. Press the settings button located on the home
screen (Figure 127).
FIG. 127
3. Press the Battery Type button (Figure 128).
FIG. 128
4. Select battery type and brand installed in machine
(Figure 129). See battery label to determine type
and brand. Press the up and down arrows to scroll
through battery selection.
FIG. 129
NOTE: The battery charger profile and battery
discharge indicator will automatically reprogram when
battery type is selected.