4.6.3 Application Select Input
Applications can be selected through external inputs. These inputs can be used in two
different schemes. The inputs can either select one of four different applications. Or,
when set to “binary”, these three inputs can be used to select eight different inputs.
Binary (1 of 8) is the first option on the “Applications Select Inputs” screen. In order to
choose this option either press the “1” key at this screen or highlight the option and press
the “Select” soft-key.
If discrete (1 of 4) is how you would prefer to select applications either press the “2” key
or highlight this option and press the “Select” soft-key.
Cleco
®
Pneumatic Torque Verifier TVP-100 Series
APPLICATION SELECT INPUTS
1. Binary, 1 of 8
2. Discrete, 1 of 4
Select
EXIT
Up
Down
Param D
Param C
Param B
Application
Application
INPUT
INPUT
INPUT
(Binary)
(Discrete)
OFF
OFF
OFF
A
A
OFF
OFF
ON
B
B
OFF
ON
OFF
C
C
OFF
ON
ON
D
C
ON
OFF
OFF
E
D
ON
OFF
ON
F
D
ON
ON
OFF
G
D
ON
ON
ON
H
D