Page 18
PL12EN-TVP100
03/07/2013
4.2 Navigation Menu
The Navigation Menu is the leaping off point to all functions within this unit. The Ship’s
Wheel key may be pressed at any time, and the Navigation Menu will appear. From
the Navigation menu, the user can go to the Run Screen, perform an AutoCal, view a
rundown, review statistics, set the units options, select the application in use, adjust any
given application, enable sequencing, perform administrative functions, and look at a
schematic that aids in external wiring.
4.3 AutoCal
In order for this unit to function properly, the thresholds and timers within the application
need to be set appropriately with regards to the tool’s pneumatic signature. The AutoCal
feature provides a very quick and easy means of performing this set-up. To reach the
AutoCal function, select “AutoCal” from the navigation menu.The Navigation Menu
If the unit was locked prior to making this selection, you’ll be prompted to enter the
password. The default password is “0 1 0 4”.
The first screen associated with the AutoCal process will inform the user that the tool must
be off and also that they should press the “Next” key. This screen also reminds the user
which application set is active. The calibration will only effect that application. At this
point, make sure the transducer is connected to both the tool and the box and also that
the tool is not running. Then press the “Next” softkey.
Cleco
®
Pneumatic Torque Verifier TVP-100 Series
AutoCal
View Run
Statistics
Options
Select Application
Application Builder
Sequencing
Administration
I/O Schematic
Run Screen
AutoCal
View Run
Statistics
Options
Select Application
Application Builder
Sequencing
Administration
I/O Schematic
Run Screen
AutoCal
Please enter your password
to contonue.
0
1
0
4
NEXT
AUTOCAL
Tool must be OFF.
Press NEXT to continue
the AutoCalibration
for Application A.
Select
Application
NEXT
EXIT