Troubleshooting
5
EN
M1<
Torque M1, threshold not reached
M1>
Torque M1 exceeded
M2<
Torque M2, threshold not reached
M2>
Torque M2 exceeded
MDTE>
Maximum distribution torque exceeded
ME>
Press-in torque too high
NECK
Socket or nutrunner break
NOT
End due to emergency stop
OFF1
Offset error, Transducer 1
P1M>
Torque in Phase 1 too high
P2M<
Torque in Phase 2 too low
P2M<
Phase 2: Torque too low
P2M>
Torque in Phase 2 too high
P2M>
Phase 2: Torque too high
P2UU
To much under- and overstep in Phase 2
P3M<
Phase 3: Torque too low
P3M>
Phase 3: Torque too high
P4M<
Phase 4: Torque too low
P4M>
Phase 4: Torque too high
PAR
Wrong parameter
PS?
Wrong parameter set
RAM
Memory error, measuring board
SA
Canceled by removal of the start signal
SeBB
No ready signal for servo
SS>
Max. number of cycles for stick-slip exceeded
TDS
Shutoff by depth sensor
TEB<
Threshold for low evaluation torque not reached
TET>
High evaluation torque exceeded
TMAX
Canceled by exceeding the max. time
TQ<
Torque too low
TQ>
Torque too high
TQSI
Safety torque exceeded
TQUE
Torque too high
TQUN
Torque too low
TTT<
Angular redundancy below min. value after time
TTT>
Angular redundancy exceeded after time
WG1D
Error in Angle Encoder 1
WIG<
Total angle too small
WIG>
Total angle too large
ZRF
Gear defective
Error message
Description