Display of the Application/Linking group
In mPro mode, the current Application/Linking group is only displayed if the function
Selecting the Applica-
tion/Linking group
is activated, see below.
Depending on the setting of the controller, the Application or Linking group is selected.
Display of the rundown data
Selecting the Application/Linking group
To be able to switch between the Applications/Linking groups in mpro mode, the
External Application / LG
Selection
must be activated on the controller.
1. Select
Navigator > Advanced > Tool Group > I/O
on the controller.
2. Activate the checkbox
External Application / LG Selection
.
3. In
Mode
select the
Tool Menu (LiveWire/CellCore)
.
4. Press <Navigator> to save the settings.
To change between the Applications/Linking groups on the tool, press
or
.
→
Only Applications/Linking groups that have already been parameterized can be selected.
Symbol
Description
Display of the currently selected Application or Linking group (mPro).
Up to 99 Applications/Linking groups can be programmed. The number on the icon
indicates which Linking group is selected.
To the right of the symbol, up to twelve characters of the name of the Application or
Linking group are displayed. If no name has been parameterized, "---" is displayed.
Display of the currently selected Application or Linking group. The parameters for this
Linking group are used for the tightening.
Symbol
Description
Linking group/Batch display
Number of tightening positions for a Linking group.
•
If there is only one Linking group, then each result is evaluated.
•
If there is more than one Linking group, the overall result of all the tightening posi-
tions is considered.
Example: 2/3
•
Current tightening position: 2
•
Total number of tightening positions: 3
Display of the torque for the current tightening.
If an arrow pointing up appears next to the symbol, the result is too high.
If an arrow pointing down appears next to the symbol, the result is too low.
Display of the angle for the current tightening.
If an arrow pointing up appears next to the symbol, the result is too high.
If an arrow pointing down appears next to the symbol, the result is too low.
Indicates that the node number or IP address of the tool is assigned twice.
Change the node number or IP address.
Summary of Contents for CellCore CCBA