background image

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • [email protected] 

16

StreetSmart Pre-Terminated FDH Cabinet

Installation Manual 

 _________________________________________________________

Manual 021814 REV A - Jan 2021

Standard Warranty

Clearfield warrants to the original purchaser of the Product sold hereunder is free from defects in material and workmanship under normal use and 

service, subject to exceptions stated herein. Product purchased is warranted as follows: Clearfield designed and branded Products are warranted for 

three (3) years: Products manufactured by Clearfield to customer prints and/or specifications are warranted for one (1) year; and any Product Clear

-

field acquires from or through a third-party manufacturer or distributor and resells to Customer as the original customer will carry the manufacturer’s 

pass-through warranty, if any. In all cases, the warranty period commences on the date of shipment to the original purchaser.

Warranty Claim Procedure

If any Product purchased from Clearfield is found defective under the above warranty, the following basic procedure must be followed:

1. 

Customer must contact Clearfield and obtain a Return Materials Authorization

2. 

Following authorization, the Customer ships the product-freight collect-to Clearfield’s manufacturing facility

3. 

Clearfield shall repair or replace the defective Product at its sole option and discretion, and return the repaired or replacement Product to Cus

-

tomer’s site, freight prepaid

Note: If the Product is not found to be defective by Clearfield, the product will be returned to the Customer and the customer billed for freight in both 

directions.

View our warranty policy here: 

https://www.seeclearfield.com/warranty.html

Limitations of Warranty

Correction of defects by repair or replacement, at the option of Clearfield Inc, shall constitute the exclusive sole remedy for a breach of this limited 

warranty. Clearfield shall not be liable under any circumstances for any special, consequential, incidental, punitive, or exemplary damages arising 

out of or in any way connected with the product or with agreement to sell product to buyer, including, but not limited to damages for lost profits, loss 

of use, or for any damages or sums paid by buyer to third parties. The foregoing limitation of liability shall apply whether the claim is based upon 

principles of contract, warranty, negligence or other tort, breach of statutory duty, principles of indemnity or contribution, the failure of any limited or 

exclusive remedy to achieve its essential purpose, or otherwise.

Clearfield will not be responsible for any labor or materials costs associated with installation or incorporation of Clearfield products at customer sites, 

including any costs of alteration, replacement or defective product, or any field repairs.

Other Limitations

Clearfield assumes no warranty liability regarding defects caused by:

1. 

Customer’s modification of Product, excepting installation activities described in Clearfield documentation

2. 

Customer re-packaging of Product for shipment to third parties or destinations other than those originally shipped to by Clearfield, or any de

-

fects suffered during shipping where the Product has been re-packaged

3. 

Customer’s installation or maintenance, excepting activities described in and performed in accordance with Clearfield documentation

4. 

Customer’s improper or negligent use or application of Product

5.  Other causes external to the Product, including but not limited to accidents, catastrophe, acts of God, government action, war, riot, strikes, civil 

commotion, sovereign conduct, or the acts or conduct of any person or persons not party to or associated with Clearfield

6.  Environmental factors and weathering resulting in aging and damage not necessary or applicable to the function of the product

Summary of Contents for StreetSmart Pre-Assigned FDH

Page 1: ...StreetSmart Pre Terminated FDH Cabinet Installation Manual _______________________________________________________ Manual 021814 REV A Jan 2021 ...

Page 2: ...___________________________________________________ Manual 021814 REV A Jan 2021 Table of Contents Application 3 Description 3 Technical Specifications 3 Mounting Base to Vault Lid 4 Mounting Cabinet to Base 6 Pole Mount Installation 7 Pre Loaded Splitters 10 Connector Cleaning Procedure 11 Standard Warranty 16 Proprietary Notice 17 Technical Support 17 ...

Page 3: ...t Pre Assigned FDH PON Cabinet provides an interconnect environment from the feeder network through the passive optical splitter to the distribution network Designed for rapid PON Network deployments these cabinets provide a single distribution point to deploy FTTH in large scale MDU s urban or dense neighbor hoods Pre Assigned WaveSmart High Density 1 x 32 Splitters are loaded into the cabinet wi...

Page 4: ...______________________________________________ Manual 021814 REV A Jan 2021 Mounting Base to Vault Lid 1 2 3 Remove the access door from the back of the cabi net base with a 7 16 socket or can wrench Remove the nuts from the threaded studs holding the cabinet to the base and lift the cabinet from the base Place the cabinet base over the hole in the vault lid ...

Page 5: ...ield com techsupport clfd net Manual 021814 REV A Jan 2021 4 5 6 Place the rectangular washer plates over the round cutouts in the cabinet base Insert the J bolts through the base of the rectangular washer plates ensuring that the J hook is hooked under a rib of the vault lid underneath Using the washers lock washers and nuts provided secure the cabinet vase to the vault lid ...

Page 6: ..._______ Manual 021814 REV A Jan 2021 Mounting Cabinet to Base 1 2 3 Feed the cables through the cabinet base and vault lid as you lower the cabinet onto the base Carefully align all the threaded studs on the bottom of the cabinet with the holes in the top of the base as you seat it into place Using the provided washers and nuts firmly secure the cabinet to the base Reinstall the base access door ...

Page 7: ...ate the toothed bracket that has the mounting holes in the flange and mount it to the cabinet below the previously installed hoist plate using the included hardware 3 Determine the top height of the cabinet Drill a 5 8 hole 8 inches below the anticipated height of the cabinet all the way through the pole Note Clearfield does not provide the mounting hardware Required hardware includes a 5 8 thread...

Page 8: ...f the pole It is suggested to add 3 to the diameter of pole for rod length Note Clearfield does not recommend using lag bolts to mount cabinet to pole Clearfield recommends using hardware with a minimum of 5 8 diameter Care should be taken to avoid over tightening and deforming the hoist plate Lock tight red should be used on nuts to prevent loosening of nuts Make sure the thread rod nut does not ...

Page 9: ...Direct 763 476 6866 National 800 422 2537 www SeeClearfield com techsupport clfd net Manual 021814 REV A Jan 2021 6 Level cabinet and drill 5 8 hole through lower bracket and pole and install 5 8 rod washers and nuts Note Care should be taken to avoid over tightening and deforming the hoist plate 7 Cabinet Fully Mounted ...

Page 10: ...s feeder leg will be connected to feeder port 1 and its distribution legs will be connected to distribution ports 1 32 Splitter 2 will connect to feeder port 2 and distribution ports 33 64 and so on for the number of splitters pre installed in the ordered configuration If you wish to pull service from a pre installed splitter leg the connector can be installed into one of the adapters in the provi...

Page 11: ...ching of the end face Learn the process of cleaning properly Note It is NOT recommended to use isopropyl alcohol to clean the end face Cleaning an SC LC Connector Cleaning the End Face Place one wiping paper on QbE 2 FiberSafe Cleaning Platen Figure 1 Apply small amount of precision cleaner about 1 in diameter with Electro Wash MX pen on to one end of the wipe Figure 2 Hold end face at a 90 degree...

Page 12: ...ter AND the Adapter Itself Lightly moisten the fiber optic swab 2 5mm 38542F or 1 25mm 38040 by spotting a small amount about 1 of Electro Wash PX or Electro Wash MX pen onto the QbE Hold the tip of the swab onto the wetted area and hold for a count of 1 2 3 4 5 Insert the swab into the adapter to the connector press lightly against the connector twist 2 3 times remove and discard Dry with a secon...

Page 13: ...pins with this or an equivalent type swab Cleans ALL MTP MPO connector end faces This swab also cleans the pins of the male connector Lightly spot a QbE 2 wipe on the platen with Electro Wash PX Fiber Optic Cleaner the FiberWash or MX Pen Lightly touch short side of the MTP MPO Connector Swab to the wetted area 3 5 secs to absorb some cleaning solution DO NOT over saturate the swab Wipe connector ...

Page 14: ...t pins Cleaned like a single fiber connector using a cleaning platform The receptacles will be cleaned as long as you are using a combination clean ing process as recommended Again using a platen moisten the platen with cleaning solvent on one end to accommodate 3 swipes of the MPO female endface Holding the connector If APC slightly at an angle to accommodate for 8 angle swiping with medium press...

Page 15: ...ace separately or through the adapter Slightly engage probe by pulling back but do not allow to click Lightly spot a QbE 2 wipe on the platen with Elec tro Wash PX Fiber Optic Cleaner this will help alleviate over saturation of the material Lightly touch the tip of probe and release Wipe Material Wet End Face Dry Insert connector or insert probe though adapter and click 2 3 times to move past the ...

Page 16: ...he option of Clearfield Inc shall constitute the exclusive sole remedy for a breach of this limited warranty Clearfield shall not be liable under any circumstances for any special consequential incidental punitive or exemplary damages arising out of or in any way connected with the product or with agreement to sell product to buyer including but not limited to damages for lost profits loss of use ...

Page 17: ...pplied Every effort has been made to keep the information contained in this document current and accurate as of the date of publication or revision However no guarantee is given or implied that the document is error free or that it is accurate with regard to any specification Technical Support Clearfield Inc can be contacted for any issues that arise with the supplied product If you need to return...