Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • [email protected]
6
FieldSmart FDP Indoor/Outdoor Wall Boxes
Installation Manual
_________________________________________________________
Manual 022793 REV A - March 2022
If optional strength clamps are used, install them onto the strain relief threads before installing the nut to tighten.
Install the nut onto the threads and tighten securely until the fitting will not rotate.
Insert cable through sealcon and tighten dome nut to compress rubber sealing grommet.
4.
5.
6.
Mid-Spanning Cable
Open your cable (Clearfield recommends opening 12ft of cable
when mid-spanning inside the Large FDP Wall Box).
Secure the cable tie-downs in place near the two mid-span en
-
trances located at the top and bottom of the wall box.
Note:
Cable tie-downs have an adhesive backing as well as holes
for screws.
1.
2.