5
FieldSmart FDP Indoor/Outdoor Wall Boxes
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • [email protected]
Manual 022793 Rev A - March 2022
Identify the location of the sealcon. On all size boxes, the seal
-
con locations have been pre-marked on the inside of the box
for easy identification. There are at least two sealcon locations
for each box.
1.
Use a drill bit (step drill is preferred tool); drill out the plastic
area enough so that the water tight strain relief fitting will fit
through the hole.
FDP Large: 1” drill bit for 3/4” sealcon
FDP Small/Mini: 7/8” drill bit for 1/2” sealcon
2.
Install the sealcon through the hole, with the threads on the inside of this box. Ensure the O-ring is in place at the top of
the sealcon’s threads prior to installation.
3.
Installing Sealcons