25 CV1450/1700/1950 Installation Guide
© Clear Vue Cyclones 2022
Pairing Your Receiver and Remote
Your receiver and remote have come paired by the manufacturer prior to shipment. Pairing is
saved for one year without power supply, but on occasion receivers/remotes do need to be
paired again upon receipt.
1.
Clear previous pairings from the receiver memory:
a. Press and hold the power button on the receiver for 5 seconds until the LED indicator
begins to flash slowly.
b. Press and hold the power button on the receiver for an additional 5 seconds until the
LED indicator begins to flash rapidly.
c. Press the power button on the remote to confirm pairing has been removed.
2.
Pairing the receiver and the remote:
a. Press and hold the power button on the receiver for 5 seconds until the LED indicator
begins to flash slowly, indicating pairing mode has been activated.
b. Press the “ON” button, then “OFF” button on your remote to complete the pairing
process.
3.
Multiple remotes can be paired with the receiver by repeating steps 1 and 2 above.
Electrical – Single-Phase Motors
Clear Vue Cyclones highly recommends the use of a professional, licensed
electrician to complete the wiring and any electrical work associated with
this installation. Significant damage to your system and/or bodily harm can result
If you purchased our prewired Electrical Box, which gives you a remote start for your system,
please refer to the assembly sheet included with this item.
Baldor recommends the use of wire lugs in lieu of wire nuts to secure all connections.
Once the motor is wired, the motor shaft and impeller blade should be turning
counter-clockwise
when viewed from below
(i.e.: looking up at the impeller from the floor).
Note that our impellers are backward inclined, allowing our system to move high volumes of air at a
variety of static pressures towards the filters or your exhaus. Each blade on the impeller has a slight
“C” shape. When rotating correctly, the convex side of the blade will be hitting the air first. This
rotation will match the yellow rotation sticker on your blower housing.
ROTATION
Please note there is a small protective tab that must be removed from the battery