①
Connect the dedicated faucet for purifier (softener) or other
faucet and the “OUT” side nipple with the pressure-resistant
blade hose.
②
Connect the dedicated stop valve
for purifier (softener) and the “IN”
side nipple with the pressure-
resistant blade hose.
For strength protection, the fixing
nuts, plate and frame plate
should be set before installation.
●
The lengths of piping between the purifier (softener) and
faucets should be less than 1m. And install the pipes in
the range not to be polluted.
●
Use one faucet per one water purifier (softener) as a principle.
●
When this system is connected with the faucet except dedicated
one, we recommend the combination with something like
automatic drainage function.
Connect the “OUT” side and “IN” side properly.
8-3. Connection
8-4. Water Flowing Test and Leakage Check
8-5. Adjustment of Filtered Water Volume
If there is a leakage from the water purifier (softener), close the stop valve, and contact
with the store where you bought Cleansui, or installation contractor.
If you attach dome nut, tighten the screw with 2 wrenches firmly.
Before that, set a rubber seal certainly.
To use water purifier (softener) properly,
the adjustment of water volume and
enough drainage time are important.
Please observe the indications.
General view of the connection
①
Fully-open the dedicated faucet for water
purifier (softener) , and then open the
dedicated stop valve for water purifier
(softener) gradually.
②
keep this situation, and drain filtered water
until the bubbles disappear from
water.(MP02-1E, 4E: About 3 minutes
Mp02-5E, 6E: About 1 minute)
③
After drainage, close the dedicated faucet
for water purifier (softener), and check
there is no leakage around the filtering
system and piping.
●
The initial drainage time is an estimated
one until the bubbles disappear.
①
Open dedicated faucet for water purifier (softener) fully.
②
Adjust the water volume with dedicated stop valve for water
purifier (softener) .
200 ml
≒
quantity of 1cup of water
MP02-1E
…
Adjust the water flow volume to about 200 ml/sec
MP02-2E
…
Adjust the water flow volume to about 200 ml/sec
MP02-3E
…
Adjust the water flow volume to about 200 ml/sec
MP02-4E
…
Adjust the water flow volume to about 200 ml/2 sec
MP02-5E
…
Adjust the water flow volume to about 200 ml/2 sec
MP02-6E
…
Adjust the water flow volume to about 200 ml/2 sec
③
After the adjustment of water volume, close the faucet for water
purifier (softener).
Adjust the water flow volume
with this dedicated stop valve for
water purifier (softener).
※
This installation instruction manual has illustrations in case of using
dedicated faucet for filtered (softened) water.
①
②
③
Fixing nut
Plate
Frame plate
Dedicated faucet
for water purifier
(softener)
Dedicated stop
valve for water
purifier
(softener)
“OUT” side
“IN” side