Failure to follow the safety precautions can lead to a serious accident. They contain extremely 
important information related to safety and all instructions must be observed without fail.

 

Warning

Attention

Prohibition

Instruction

The articles with this mark 
indicates possible serious 
injury or fatal accident.

Indicates “prohibited” actions.

Indicates “mandatory 
instructions”.

Indicates failure to observe 

these instructions can cause 

minor injury to the user or 

damage to surrounding 

property.

The degrees of potential danger and damage that can be caused from any improper 
use or ignoring the contents of the safety precautions are explained below.

1. Safety Precautions

Attention

Do not use this device to filter hot water above 35

.

Do not use filtered water in fish tanks, etc.

When the filtration performance declines through usage, residual
chlorine may remain in filtered water. This may be fatal to fish.

Do not apply strong force or shock to the water purifier
(softener) and connection.

Keep the heated appliances (frying pan etc.) away from
the water purifier (softener), pipes and hoses.

It causes damage or leakage, and that may result in property damage.

If you have not used the purifier (softener) for more than
half a month, please replacethe cartridge.

Do not touch the “pure water” outlet with your hand or
cloth.

If the wateroutlet becomes soiled by splash back etc. Run
filtered (softened) water for 15 seconds.

For the maintenance of the wateroutlet, clean with a
sterilized soft toothbrush etc.

If you do not keep the wateroutlet clean all the times, bacteria may
multiply.

Do not use detergent and organic solvents (thinners
gasoline etc.) for cleaning.

Please use wet towel etc. for cleaning.

If seasonings that contain salt, sticks to the stainless steel
parts, wipe with a clean damp cloth to remove salt.

Please confirm there is no leakage around connections
and water purifier (softener) once a month.

It is not recommended that customers attempt disassembly
or repairs themselves. Contact your supplier.

It is recommended that the area around the unit be
waterproof to avoid damage should leakage occur.

The ambient temperature must be less than 60

.

The heat may warp and break the water purifier (softener), and that may
cause leakage.

If the working water pressure is more than 0.35MPa,
please adjust it to 0.2MPa with a reducing valve.
(Reducing valve is not included.)

Warning

Attention

Please use tap water that meets the local standards for
drinking water.

It cannot be used to purify hot-spring water, well water or any other
water that contains large amounts of impurities. Uses of the water filter
in this way may be detrimental to your health.

Please consume filtered (softened) water as soon as
possible.

Hollow fibre membrane units MP01-1E and MP02-4E are
recommended for use in ice machines and cold drink
vending machines.

Replace the cartridge regularly.

Recommended purifier cartridge replacement period is 12 months and in
the case of the softener cartridge, it is 6 months. Continuous usage of
the cartridge which is exhibiting reduced water volume output, due to
clogging, may cause damage and leakages, which may result in property
damage. Water purifying performance may not be adequate with the
cartridge that has passed the recommended replacement period.

When you start using a new cartridge, please let the water
flow until there are no more bubbles in the water (About 3
minutes for MP02-1E, 4E, about 5 minutes forMP02-2E, 3E).
Also confirm that there is no leakage at the same time.

To remove the retained water, please let the water flow for
about 2 minutes in the cases of MP02-2E and 3E, about 30
seconds in the cases of MP02-1E, 4E, 5E, 6E before using
everyday.

When the red water flows from tap after cutting the water
supply, you should not put this water through the water
purifier (softener).

If you let the red water flow through the water purifier (softener), the
performance will be considerably impacted.

This system must be used with the dedicated cartridge.

This system must not be installed at any location where it
might become frozen.

This system is not assumed to be used in cold districts.

Don't touch the water purifier (softener) when leakage is
evident.

It causes a short circuit and you may get an electric shock.

Summary of Contents for MP02-1E

Page 1: ...heck 8 5 Adjustment of Filtered Water Volume Warranty Thank you very much for purchasing Cleansui MP02 series Read these instructions carefully before use An installation instruction and warranty are...

Page 2: ...nded that the area around the unit be waterproof to avoid damage should leakage occur The ambient temperature must be less than 60 The heat may warp and break the water purifier softener and that may...

Page 3: ...supply valve Dedicated stop valve for water purifier softener Clamp OUT side IN side Stain steel container with a cartridge This instruction manual has illustrations in case of using dedicated faucet...

Page 4: ...the hardness components in tap water calcium magnesium It also removes free residual chlorine and unpleasant odours etc MP02 5E 5 000L MP02 6E 3 000L Specifications Model No Cartridge Model Number Mat...

Page 5: ...ess etc Water volume decreased steeply clogging You experience an unpleasant taste or odour filtration performance becomes lower It is recommended that a plumber facilitate the cartridge replacement T...

Page 6: ...urifier softener Fully opened Fully open the dedicated faucet for water purifier softener gradually And drain water in order to remove the inside air and wash the filtration components MP02 1E 4E 3 mi...

Page 7: ...d cartridge counter clockwise left and remove it Turn the new cartridge clockwise right more than 2 revolutions and screw in completely Appropriate water flow rate MP02 1E About 200 ml sec MP02 2E Abo...

Page 8: ...uses There is a leakage from connection There is a leakage from water purifier softener Connection is incorrectly done The main body of the water purifier softener may be damaged Before asking for a s...

Page 9: ...nt blade hose or flexible pipe 2 Dedicated faucet for water purifier softener 1 Stop valve 1 T joint with a nut 1 At plumbing connection and installment of dedicated faucet for water purifier softener...

Page 10: ...carefully MP02 5E and MP02 6E cannot be used in horizontal position Set the water purifier softener to the mounting frame The purifier softener should be touching the floor as the appropriate positio...

Page 11: ...f the connection Fully open the dedicated faucet for water purifier softener and then open the dedicated stop valve for water purifier softener gradually keep this situation and drain filtered water u...

Reviews: