9
8
4
Pouring
Clean the pitcher, funnel and lid periodically. Wash the pitcher, funnel and lid with a
clean sponge and neutral kitchen detergent. Rinse thoroughly.
5. Replacing the Filter Cartridge (ACPC5-D)
Pull upward to detach filter cartridge.
Insert new filter cartridge and press into position. Follow installation instructions (pg.7)
The filter cartridge replacement period is approximately 3 months, however, this period may vary based
on the amount of water used, water quality and the temperature of water filtered (colder water needs
longer filtering). In general, use your filter counter as a guide for replacement, but earlier replacement
is recommended in the following circumstances:
• When the odor or taste of chlorine is detected
• If the unit has not been used for a long period of time
6. Maintenance
Clean the pitcher, the funnel and the lid periodically.
●
Wash with a clean sponge and neutral kitchen detergent, and then rinse off thoroughly. Failure to rinse
thoroughly may result in cracks or deteriorated water quality.
7. Specifications
Product Name
Water Filtration Pitcher
Model number
AJP407-D
Material
Body: SAN (AS)
Cartridge: ABS
Lid: PP, ABS
Funnel: MBS
Filter components
Hollow fiber membrane, Activated carbon, Ion exchanger
Working Pressure (min/max)
Capacity
Service flow rate
Filtered water temperature (min/max)
Electrical requirements
Replacement cartridge
Atmospheric
26.4gallons (100L)
0.1L/min
33°F/95°F (1°C/35°C)
none
ACP5-D
AJP407-D Performance Data Sheet
Cleansui Reduction Data
NSF/ANSI Standard Requirements
Substance
Overall persentage reduction
Influent challenge
concentration
Reduction requirement /
Maximum permissible product
water concentration
NSF/ANSI Standard 42 - Aesthetic Effects
Chlorine
97.1 %
2.0 mg/L ± 10 %
≧
50 %
Maintenance according to the manufacturer’s instructions is critical for proper filter performance. Filter life
should not exceed 26.4 gallons. If filtering time is notably increased, replace the cartridge earlier.
This system has been tested according to NSF/ANSI standard 42 standards by NSF International for reduction
of the substances listed above. The concentration of the indicated substances in water entering the system
was reduced less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI
standard 42.
The system conforms to NSF/ANSI standard 42 for specific performance claims as verified and substantiated
by test data. While testing was performed under standard laboratory conditions, actual performance may vary.
The use of this system need comply with applicable state and local laws.