22
Cleanfix —KS 1100—simply clean
Fuses
Safety Information:
Relays
There is an integrated contact
F = Filter cleaning in the drivers seat.
S = Side brushes
The Ride-on-Sweeper cannot be
B = Blower/Vacuum pump
driven or other switch functions
C = Cylindrical brush
used unless someone is seated
L = Light
and the seat contact is activated
Safety fuses
The fuse box is on the right side of the Ride-on-Sweeper under the main machine cover,
underneath the cylindrical-brush lever.
Never repair fuses.
Never replace fuses by stronger ones (for higher Amps).
This would lead to damage to the electrical equipment.
It can lead to a short circuit and under the circumstances even lead to a fire.
Wheels and Steering
The steering of the front wheel is actuated by a chain and chain pinion.
The Ride-on-Sweeper has total three wheels. The wheels of the Ride-on-Sweeper are
Gel-wheels and help ease the adjustment of the cylindrical brush and side brushes.
(air filled wheels loose air and cause the machine to have different operation heights)
The wheels and steering have to be greased regularly with a grease gun/grease press.
For this maintenance job please abide to the Maintenance chart on the following page.
Cylindrical brush drive
The cylindrical brush drive is on the right side of the Ride-on-Sweeper (drive direction
view) The cylindrical brush is driven via a chain by an electric motor. The chain is diverted
over a chain wheel and driven by chain wheels of the cylindrical brush. A spring-loaded
chain tensioner holds the chain under tension.
Grease the chain wheels in regular intevals.
See the Maintenance Chart on the next page.
In order to grease the chain wheels, open the machine‘s main cover and remove the side
covers. Please refer to the Maintenance Chart on the next page.
F S B C
L
12A
20A 20A 30A 20A
12A 25A
25A
20A
11
Cleanfix —KS 1100—simply clean
Sweeping operation
Vacuum operation
Vacuum operation helps preventing
Dust accumulation when sweeping.
•
Start the Ride-on-Sweeper
•
Switch on the Tipp switch for the suction
motor. A control light will shine on the
switch. The suction operation begins.
Attention!
Do not switch on the vacuum motor
when cleaning wet areas/wastes. It
will cause damage to the vacuum motor.
- To end the vacuum operation switch the
Tipp switch to Vacuum motor OFF.
Filter cleaning operation
The filter cleaning—vibration device
prevents that lamellas of the filter do
not clogg up with dust.
Switch off the vacuum operation. Wait
until the ventilator wheel stops and
stands still.
Activate the filter cleaning-
vibration device.
Press the Tipp switch 5-10 seconds long
for the filter cleaning.
The filter cleaning begins to work.
Operator panel
(without overhead disposal)
Switch for the side brushes
Lever to open a flap and
Switch for the cylindrical brush allow large wastes enter
Switch for cylindrical brush
(Wastes till
65mm)
Emergency Off Main Switch
E.g. small PET bottles,...
Switch for filter cleaning
ON and OFF key switch
Battery charge—status indication
Switching off the Ride-on-Sweeper
•
Press the brake pedal
•
Secure the brake by pressing
additionally the small brake pedal
(„hand-brake) into the latch.
If the brake is released afterwards, then the
brake pedal must be kept pressed down.
•
Switch off all power supply
•
Lift up both side brushes by using
both levers on the steering column.
•
Latch the lifting/lower level for the
cylindrical brush.
•
Turn the key into position 0 = OFF
and take the key out.
Turn the battery main switch OFF and
take it out of the holder.
Danger!
Inappropriate use of the Ride-on-Sweeper
can lead to severe injuries to persons and
heavy damage to the equipment!
Prevent unauthorized persons to use the
Ride-on-Sweeper.
Never leave the operational Ride-on-
Sweeper unsupervised.
Pull out the battery mains switch key and
the key of the ON/OFF switch when leaving
the machine unattended.
(e.g. at the end of a job or days work the key
should be removed)
Keep the Mains Switch key and ON/OFF
key switch in separate places