__________________________________________________________________________________
7
8. Storage
All parts of a Clean-air system must be stored in
environment with temperature range 0-40°C and
humidity range 20-80% Rh. The storage life is 2
years for the product if stored in original unopened
package.
NOTE: Batteries get discharged even if not in use.
Therefore in case of a long-term storage it is fully
recommended to charge the NiMH batteries every
12 months.
9. Warranty
There is a 12 month warranty covering production
defects , a 6 month warranty for batteries.
Warranty begins from the date of purchase. The
claim must be lodged at the dealer’s place. The
invoice or receipt must be declared if claiming the
warranty.
The claiming procedure will be successful only on
condition that there were no changes made on the
blower unit incl. the battery and charger.
If the damage is caused by not changing a clogged
filter in good time or using a filter which has been
cleaned by the customer, the claim will not be
proceeded.
10. Technical
data
CA BASIC 2000
CAB DUAL FLOW
CAB FLOW CONTROL
Airflow
160* - 140 l/min
200* - 180 l/min
140 to 210 l/min
(at 8 adjustable flow rates)
* with fully charged attery and clean filters
Weight of the blower unit incl. the
filter and battery
900 g
Noisiness
55 - 61 dB
NiMh battery lifetime
500 to 700 charging cycles
One charging cycle
10 to 14 hours
Belt size
80 to 100 cm
Recommended temperature range
10°to 40°C
Recommended humidity range
20 to 80 % Rh
Certification
EN 12 941 TH1
EN 12 941 TH2/TH3
Airflow Filter
Expected operating time of the blower unit
after being fully charged (hours)
middle max middle PSL
X
11-12 h
CA BASIC DUAL FLOW
X
6 h
X
10 h
X
6-7 h
CA BASIC FLOW CONTROL
X
4-5 h
NOTE! operating time can be
shortened in case of clogged filter
or undercharged battery
CA CHEMICAL
CACH DUAL FLOW
CACH FLOW CONTROL
Airflow
140* a 200* l/min
60, 80, 100 l/min – mask mode
120,140,160 l/min – hood mode
* with fully charged attery and clean filters
Weight of the blower unit incl. the
filter and battery
1 050 g
1 150 g
Noisiness
55 to 61 dB
NiMh battery lifetime
500 to 700 charging cycles
One charging cycle
10 to 14 hours
Belt size
75 to 130 cm
Recommended temperature range
10°to 40°C
Recommended humidity range
20 to 80 % Rh
Certification
EN 12 941 TH1
EN 12 942 TM3
EN 12 941 TH2/TH3
EN 12 942 TM3