Operator's Manual: Model CB-1400
4-25
Figure 4Q - Installation of the Optional Draft Inducer
Installing the Optional Draft Inducer (continued)
I88835
SERVICEMAN ADJUSTS
DRAFT OVERFIRE
CHECK FOR −0.02 W.C.
BREECH SO THE MOTOR DOES NOT
DRAFT INDUCER AWAY FROM FURNACE
SECTION OF VERTICAL STACK TO POSITION
NOTE: INSTALL DRAFT INDUCER IN LAST
OVERHEAT. THIS ALSO REDUCES ASH
DO NOT MOUNT THE DRAFT INDUCER IN THE
HORIZONTAL STACK NEAR THE FURNACE
ACCUMULATION IN THE DRAFT INDUCER.
BREECH.
DRAFT INDUCER
ADJUSTMENT
PLATE
DRAFT
"CLASS A" STACK
BAROMETRIC DAMPER TO
OBTAIN −.02 W. C. DRAFT
OVERFIRE
SI
N
G
LE
W
AL
L
24
G
A
U
G
E
INT
E
RIO
R
S
T
A
CK
5
FE
ET
−
8
F
EE
T
OPTIONAL
Installing the Draft Inducer
WARNING:
Turn OFF the main power to the furnace before proceeding with the installation of
the draft inducer.
ATTENTION:
It is very important to install the draft inducer on a vertical section of stack to isolate the
inducer from excessive heat and ash buildup. Never install the draft inducer on a horizontal section of stack
close to the furnace breach where heat and ash will damage the inducer motor.
1.
Refer to Figure 4Q. Follow the instructions included with the draft inducer to mount the draft
inducer on the section of single-wall vertical stack.
2.
Position the draft plate all the way out so that it does not reduce the draft produced by the draft
inducer. You will adjust the draft plate later as part of
Adjusting the Draft Overfire
(Section 8).
Summary of Contents for CB-1400
Page 2: ......
Page 8: ......
Page 18: ...Operator sManual ModelCB 1400 1 10 ...
Page 62: ...Operator sManual ModelCB 1400 5 8 ...
Page 68: ...Operator sManual ModelCB 1400 7 2 ...
Page 84: ...Operator sManual ModelCB 1400 9 10 ...
Page 92: ...Operator sManual ModelCB 1400 10 8 ...
Page 108: ...Operator sManual ModelCB 1400 C 2 ...