INSTALLATION CLEARANCES FOR MANTLEPIECES
VICTORIAN FIREPLACE INSERT - GENERIC MANTLEPIECE
MEDIUM VICTORIAN
LARGE VICTORIAN
NOTES:
1. All dimensions are in millimetres.
2. Clearances are to combustible materials and are a minimum.
3. The minimum distance between the hot air outlet and underside of mantle shelf is 600 mm for the
medium Victorian and 580 mm for the large Victorian.
4. The heat shield and key shield, as specified above, must be used to maintain clearances.
Ensure heat shields extend the width and depth of underside of mantle shelf and key.
5. Clean Air Woodheaters tested by HRL Technology P/L to comply with Australian Standards
when installed to enclosed dimensions. Test Reports: Medium HCMG/04/025 & Large
HCMG/04/026.
DIAGRAMS ARE NOT TO SCALE
Page 11
225
595
800
60
60
250 max
600
min
HOT AIR
OUTLET
KEY SHIELD
100 x 30 x 1 mm
sheet metal
480 D x 950 W
HEAT SHIELD
Min. 1070 mm wide x
0.6 mm sheet metal
FLOATING
ISOLATOR
PANEL
25
max
10
2
235
645
900
60
60
250 max
580
min
HOT AIR
OUTLET
KEY SHIELD
100 x 30 x 1 mm
sheet metal
480 D x 1050 W
HEAT SHIELD
Min. 1070 mm wide x
0.6 mm sheet metal
FLOATING
ISOLATOR
PANEL
25
max
10
2
HEARTH: 2 x
6 mm cement
sheet & tiles
HEARTH: 2 x
6 mm cement
sheet & tiles
Summary of Contents for Edwardian Large
Page 18: ...BUILDERS NOTES Page 18 ...