STANDARD FIREPLACE INSERT - GENERIC MANTLEPIECE
MEDIUM STANDARD
LARGE STANDARD
NOTES:
1. All dimensions are in millimetres.
2. Clearances are to combustible materials and are a minimum.
3. The minimum distance between the hot air outlet and underside of mantle shelf is 330 mm. For
distances over 600 mm, no heat shield is required.
4. The heat shields, as specified above, must be used to maintain clearances. Ensure heat shields
extend the width and depth of underside of mantle shelf and key.
5. Clean Air Woodheaters tested by HRL Technology P/L to comply with Australian Standards
when installed to enclosed dimensions. Test Reports: Medium HCMG/04/025 & Large
HCMG/04/026.
DIAGRAMS ARE NOT TO SCALE
Page 9
INSTALLATION CLEARANCES FOR MANTLEPIECES
110
595
960
25
25
250 max
HEAT SHIELD
Min. 1070 mm wide x
0.6 mm sheet metal
FLOATING
ISOLATOR
PANEL
HOT AIR
OUTLET
480 D x 950 W
180
min
330
min
HEAT SHIELD
10
10
75 max
110
645
1060
25
25
250 max
HEAT SHIELD
Min. 1070 mm wide x
0.6 mm sheet metal
FLOATING
ISOLATOR
PANEL
HOT AIR
OUTLET
480 D x 1050 W
180
min
330
min
HEAT SHIELD
10
10
75 max
HEARTH: 2 x
6 mm cement
sheet & tiles
HEARTH: 2 x
6 mm cement
sheet & tiles