EDWARDIAN FIREPLACE INSERT - GENERIC MANTLEPIECE
MEDIUM EDWARDIAN
LARGE EDWARDIAN
NOTES:
1. All dimensions are in millimetres.
2. Clearances are to combustible materials and are a minimum.
3. The minimum distance between the hot air outlet and underside of mantle shelf is 330 mm. For
distances over 600 mm, no heat shield is required.
4. The heat shields, as specified above, must be used to maintain clearances. Ensure heat shields
extend the width and depth of underside of mantle shelf and key.
5. Clean Air Woodheaters tested by HRL Technology P/L to comply with Australian Standards
when installed to enclosed dimensions. Test Reports: Medium HCMG/04/025 & Large
HCMG/04/026.
DIAGRAMS ARE NOT TO SCALE
Page 10
INSTALLATION CLEARANCES FOR MANTLEPIECES
110
595
800
60
60
250 max
HOT AIR
OUTLET
480 D x 950 W
180
min
HEAT SHIELD
Min. 1070 mm wide x
0.6 mm sheet metal
FLOATING
ISOLATOR
PANEL
HEAT SHIELD
330
min
75 max
10
10
110
645
900
60
60
250 max
HOT AIR
OUTLET
480 D x 1050 W
180
min
HEAT SHIELD
Min. 1070 mm wide x
0.6 mm sheet metal
FLOATING
ISOLATOR
PANEL
HEAT SHIELD
330
min
75 max
10
10
HEARTH: 2 x
6 mm cement
sheet & tiles
HEARTH: 2 x
6 mm cement
sheet & tiles