Lithium Power Supply User Manual
Page
9
Table 2
Protection Class
Class I
(Do only connect to a Residual-current device (RCD) protected source)
Certifications
•
2014/35/EU (Low voltage directive)
EN 62368-1: 2014 (Safety, Information technology equipment)
•
2014/30/EU (EMC directive);
EN 61000-6-3: 2007 + A1:2011 Emission household
equipment
EN 61000-6-2: 2005 Immunity industrial
Safety protections
•
230vac Input protected by 10AT fuse
(Not replaceable)
•
230vac Output Protected by 2 x 8A fuse
(Resetable)
•
DC Input Protected by 3 x 40A ATO fuses
(replaceable)
•
DC Output Protected by 3 x 40A ATO fuses
(replaceable)
•
Lithium battery protected by fuse
(Not replaceable)
•
L/N relay hazard is hardware protected.
•
PE/N relay hazard is hardware protected.
Additional
protections
230vac AC Output protections
•
Overload
•
Short circuit
230vac AC Input protections
•
Over / Under voltage
•
Frequency
•
Controlled charge levels
DC Input
•
Over / Under voltage
•
Overload
•
Controlled charge levels
DC Output
•
Overload
•
Controlled charge levels
(reverse on output)
Internal Lithium battery protections
•
Over charge
•
Deep discharge
•
Temperature
•
Overload