background image

 

Hy B-Eye series 

– User Menu

 

6

 

SET UP MENU 

Setup 

–  Pixel Engine – DMX ADDRESS 

It  lets  you  select  the  address  (DMX  Address)  for  the  
control    signal    by  PIXELS  ENGINE.  A  DMX  address 
between 001 and 512 can be selected. 

Permette di  selezionare  l'indirizzo  (DMX  Address)  per  il  
segnale    di  controllo  della  parte  relativa  al  PIXELS 
ENGINE,  è  possibile  selezionare  un  indirizzo  DMX 
compreso tra 001 e 512. 
 

Setup 

–  Repeat on DMX - ENABLEMENT 

It    lets    you    enable/disable    the    transmission    of    the  
Ethernet    protocol    by  DMX  signal  to  all  the  connected 
projectors. 

 

Disabled: DMX transmission disabled. 

 

Enabled on primary: DMX transmission enabled. 
 

Permette  di  abilitare/disabilitare  la    trasmissione    del  
protocollo  Ethernet tramite segnale DMX a tutti i proiettori 
connessi. 

 

Disabled: Trasmissione DMX disabilitata. 

 

Enabled on primary: Trasmissione DMX abilitata. 

Setup 

–  Repeat on DMX - UNIVERSE 

It  lets  you  set  the  “DMX  Universe”  to  assign  values 
between 000 and 255 to a series of projectors. In this case 
it refers to an Art-net input not read by the projector and re-
transmitted to other projectors. 

Permette  di  impost

are  il  “DMX  Universe”  da  assegnare  

ad  una  serie  di proiettori, valori compresi tra 000 e 255. 
In questo caso si fi riferimento ad  un  ingresso Art-net non 
recepito dal proiettore e ritrasmesso ad altri proiettori. 
 

Setup - ETHERNET INTERFACE 

It  lets  you  set  Ethernet  settings  to  be  assigned  to  the 
projector as indicated below: 
 
CONTROL PROTOCOL 
It  lets  you  select  the  “Control  Protocol”  Art-net  to  be 
assigned  according  to  the  control  unit  used;  the  options 
available are the following: 

 

Disabled 

 

Art-net on IP 2 

 

Art-net on IP 10 

 

Art-net Custom IP 

 

If the Control Protocol option is set on Disabled, when an 
IP  address  (IP2,  IP10  or  IP  Custom)  is  selected,  the 
projector  immediately  initializes  the  IP  address  that  was 
just selected. 
If the Control  Protocol  option is enabled (IP2IP10  or IP 
Custom
)  and  a  new  one  is  selected  that  is  different  from 
the previous one, the projector must be restarted so that it 
will be correctly initialized.

 

 
 
CUSTOM IP ADDRESS 
It  lets  you  to  set  the  select  the  “IP  Address”  Art-net  to  be 
assigned,  according  to  the  control  unit  used,  with  values 
between 000 and 255. 
 
CUSTOM IP MASK 
It  lets  you  to  set  the  select  the  “IP  Mask”  Art-net  to  be 
assigned,  according  to  the  control  unit  used,  with  values 
between 000 and 255. 
 

Permette  di  impostare  le  impostazioni  Ethernet  da 
assegnare al proiettore qui di seguito indicate: 
 
CONTROL PROTOCOL 
Permette  di  selezionare  il  “Control  Protocol”  Art-net  da 
assegnare  in  base  alla  centralina  di  controllo  utilizzata,  le 
opzioni disponibili sono le seguenti: 

 

Disabled 

 

Art-net on IP 2 

 

Art-net on IP 10 

 

Art-net Custom IP 

 
Se l’opzione Control Protocol è settata su Disabled, alla 
selezione  di  un  indirizzo  IP  (IP2,  IP10  o  IP  Custom),  il 
proiettore  inizializza  immediatamente  sull’indirizzo  IP 
appena selezionato. 
Se  l’opzione  Control  Protocol  è  abilitata  (IP2,  IP10  o  IP 
Custom
)  e  se  ne  seleziona  una  nuova  diversa  da  quella 
precedente,  è  indispensabile  riavviare  il  proiettore  per  far 
sì che venga inizializzato correttamente. 
 
 
CUSTOM IP ADDRESS 
Permette  di  seleziona

re  l’  “IP  Address”  Art-net  da 

assegnare  in  base  alla  centralina  di  controllo  utilizzata, 
valori compresi tra 000 e 255. 
 
CUSTOM IP MASK 
Permette di selezionare l’ “IP Mask” Art-net da assegnare 
in  base  alla  centralina  di  controllo  utilizzata,  valori 
compresi tra 000 e 255. 

Setup - FIXTURE ID 

It  lets  you  set  the  “Fixture  ID”  to  be  assigned  to  the 
projector. An “ID” between 000 and 255 can be assigned. 

Permette  di  impostare  il  “Fixture  ID”  da  attribuire  al 
proiettore, è possibile assegnare un “ID” compreso tra 000 
e 255. 
 

 

 

Summary of Contents for HY B-EYE K15

Page 1: ...t net Kling Net Universe 0 255 DMX Address 1 512 Repeat on DMX Enablement Disabled Enabled on primary Universe 0 255 Ethernet Interface Control Protocol Disabled Art net on IP 2 x x x Art net on IP 10 x x x Custom IP Custom IP Address IP address byte 1 IP address byte 2 IP address byte 3 IP address byte 4 0 255 0 255 0 255 0 255 Custom IP Mask IP mask byte 1 IP mask byte 2 IP mask byte 3 IP mask b...

Page 2: ...Invert Pan On Off Invert Tilt On Off Swap Pan Tilt On Off Encoder Pan Tilt On Off P T Homing mode Standard Sequenced Pan Home Def Pos 0 degree 90 degrees 180 degrees 270 degrees Tilt Home Def Pos 0 12 5 25 50 75 87 5 100 Silent Mode Standard Quiet Theater Fan Speed Mode Auto Full Display On Off ...

Page 3: ... 0 Halogen Mode Halogen OFF Halogen Lamp 1 Halogen Lamp 2 Halogen Lamp 3 Halogen Lamp 4 Halogen Lamp 5 PWM Frequency 1000Hz 1500Hz 2400Hz 3700Hz 5600Hz 9400Hz 15100Hz 21400Hz 31000Hz 43700Hz Emulates K10 K20 Disable Enable Setting Default Preset Reset To Default Go Back User Preset 1 Load preset 1 Save to preset 1 User Preset 2 Load preset 2 Save to preset 2 User Preset 3 Load preset 3 Save to pre...

Page 4: ...entage Fans Monitor PwrSp Speed RPM PwrSp Speed RPM Head Speed RPM Head Speed RPM Head Speed RPM Head Speed RPM RDM Unique ID ID xxxxxxxxxxxx Sensor Status Pan ON OFF n a Tilt ON OFF n a Zoom Rotation ON OFF n a Zoom ON OFF n a Network parameters IP Address IP Mask MAC Address MANUAL CONTROL Reset Yes No Channels Value Percentage TEST Pan Tilt Colour Zoom Rotation All Zoom Rotation Sensor Test ADV...

Page 5: ...resi tra 000 e 255 Questa opzione è valida solo in caso di Source Art net Setup Basic Engine DMX ADDRESS It lets you select the address DMX Address for the control signal by BASIC ENGINE A DMX address between 001 and 512 can be selected NOTE Without the DMX input signal the displayed address DMX Address blinks Permette di selezionare l indirizzo DMX Address per il segnale di controllo della parte ...

Page 6: ...P2 IP10 or IP Custom is selected the projector immediately initializes the IP address that was just selected If the Control Protocol option is enabled IP2 IP10 or IP Custom and a new one is selected that is different from the previous one the projector must be restarted so that it will be correctly initialized CUSTOM IP ADDRESS It lets you to set the select the IP Address Art net to be assigned ac...

Page 7: ...12 5 25 50 75 87 5 100 INVERT PAN Permette di abilitare ON l inversione del movimento Pan Selezionare OFF per non abilitare o disabilitare questa opzione INVERT TILT Permette di abilitare ON l inversione del movimento Tilt Selezionare OFF per non abilitare o disabilitare questa opzione SWAP PAN TILT Permette di abilitare ON l inversione dei canali Pan e Tilt e contemporaneamente Pan fine e Tilt fi...

Page 8: ...base si spengono completamente Option FAN SPEED MODE Allows you to set how to manage the fan speed of the head of the fixture select between the two available Auto the head s fan varies the speed depending on the temperature detected on the LED Full the head s fan is always at full speed Permette di impostare come gestire la velocità potenza della ventola nella testa del proiettore selezionando un...

Page 9: ...MA Lets you select three different RGBW gamma curves see details below Gamma 1 0 Gamma 1 5 Gamma 2 0 PAN TILT SPEED Permette di selezionare due differenti velocità di movimento di Pan e Tilt Normal Fast DIMMER CURVE Permette di selezionare quattro differenti curve del canale Dimmer vedi dettagli qui di seguito Curve 1 Curve 2 Curve 3 Curve 4 RGB GAMMA Permette di selezionare tre differenti curve g...

Page 10: ...e selezionare cinque differenti simulazioni di lampada alogena Halogen OFF Halogen Lamp 1 750 W Halogen Lamp 2 1000 W Halogen Lamp 3 1200 W Halogen Lamp 4 2000 W Halogen Lamp 5 2500 W EMULATES K20 Permette di emulare la luminosità degli A leda B Eye K10 o A leda B Eye K20 se abilitata Option SETTINGS Used to save 3 different settings of the items in the option menu and relevant submenus Default pr...

Page 11: ...nter Conta il numero di ore parziali di vita del proiettore dall ultimo azzeramento ad oggi Premere OK per resettare il contatore parziale sul display appare un messaggio di conferma Are you sure Selezionare YES per confermare la cancellazione Information LED ENERGY TOT Lets you view total LED working hours total and partial Watts hour Total Total LED working hours from construction to date Partia...

Page 12: ...eck the correct operations of each sensor installed in the projector each channel is associated with one of the following three parameters n a sensor not available it could be that are not used sensor on that effect ON Sensor reading It means the magnet is positioned on the sensor OFF Sensor is not reading It means the magnet is not positioned on the sensor Permette di verificare il corretto funzi...

Page 13: ...l CHANNEL It lets you set the channel DMX levels from the projector control panel value between 0 and 255 bit or between 0 and 100 Permette di impostare il livello DMX dei canali dal pannello comandi del proiettore valore compreso tra 0 e 255 bit oppure tra 0 e 100 TEST MENU It lets you test the correct operations of effects using pre saved Tests Permette di verificare il corretto funzionamento de...

Page 14: ...onferma Are you sure Selezionare YES per confermare apparirà l elenco dei proiettori disponibili e selezionabili oppure NO per non eseguire tale operazione Advanced CALIBRATION It lets you make small mechanical adjustments on some effects to perfectly align projectors from the control panel Factory default It lets you restore default Calibration values 128 bit on all channels Permette di eseguire ...