background image

5

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

ELECTRICAL CONNECTIONS

Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply 
through an approved BS1363/A plug fitted with a BS1362 13 amp fuse.

If the plug has to be changed because of damage, it must be removed and a 
replacement fitted, following the wiring instructions shown below. The old plug 
must be discarded safely, as insertion into a power socket could cause an 
electrical hazard.

• The BLUE wire must be 

connected to the 
terminal which is 
marked N or coloured 
black.

• The BROWN wire must 

be connected to the 
terminal which is 
marked L or coloured 
red.

• The YELLOW AND 

GREEN wire must be 
connected to the terminal which is marked E or

 or coloured green.

We strongly recommend that this machine is connected to the mains supply 
through a Residual Current Device (RCD)

If you are not sure, consult a qualified electrician. DO NOT try to do any 
repairs. 

WARNING: READ THESE ELECTRICAL SAFETY INSTRUCTIONS 
THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS 
SUPPLY.

WARNING: WIRES IN THE MAINS LEAD ARE COLOURED IN 
ACCORDANCE WITH THE FOLLOWING CODE: 
GREEN/YELLOW = EARTH, BLUE = NEUTRAL, BROWN = LIVE. 

Plug must be BS1363/A approved.

Always fit 

Ensure that the outer sheath of 

Neutral

(Blue)

Live

(Brown)

Earth

(Green and 

a 13 Amp 

the cable is firmly held by the clamp

fuse.

Yellow)

Summary of Contents for XR60

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0813 PARAFFIN DIESEL HEATER MODEL NO XR60 PART NO 6931002...

Page 2: ...er Proper combustion depends upon this air flow therefore the heater must not be revised modified or operated with parts removed or missing Likewise safety systems must not be circumvented or modified...

Page 3: ...ing material at least 1 inch thick and extending 3 feet or more beyond the heater in all directions 4 Keep any combustible materials such as curtains and furniture a safe distance away from the heater...

Page 4: ...s toxic CO can build up in a confined spaces and failure to provide adequate ventilation can be fatal The early symptoms of asphyxiation caused by inadequate ventilation are Be sure to follow all warn...

Page 5: ...k The BROWN wire must be connected to the terminal which is marked L or coloured red The YELLOW AND GREEN wire must be connected to the terminal which is marked E or or coloured green We strongly reco...

Page 6: ...ft 3 m from canvas or plastic coverings and secure them to prevent movement 7 Make sure that the heater is not directly exposed to rain or water spray 8 Never use in living spaces and or where childre...

Page 7: ...ke service department part number GF0K070000 3 Fill the fuel tank with clean diesel or paraffin In cold weather condensation may develop in the tank if the tank is empty and it is recommended that a t...

Page 8: ...heater by setting the power switch to the ON position The switch illuminates in the ON position 6 Adjust thermostat to desired setting NOTE Heater will cycle on off to maintain an even temperature HEA...

Page 9: ...essentially yellow There is no strong disagreeable odor eye burning or other physical discomfort There is no smoke or soot internal or external to the heater There are no unplanned or unexplained shu...

Page 10: ...fficulty getting your heater to ignite This heater should never be operated without the filters in place If required clean the filters as follows ACCESSING THE FILTERS 1 Make sure that the plug is rem...

Page 11: ...olid object to remove contaminates NOTE Compressed air or liquids should not be used to clean this filter NOTE If the filter appears damaged or extremely dirty replace it with a new filter of the same...

Page 12: ...eater fails to start 1 Check fuel level 2 Check the mains plug is correctly fitted and that the fuse inside it has not blown 3 Return to Clarke service department for repair 3 Flashes High limit switc...

Page 13: ...13 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com WIRING DIAGRAM...

Page 14: ...ONS Model XR60 Burn Rate Btu hr 50 000 Fuel consumption 1 6 L hr Approx Running Time 9 4 hr Electrical input 230V 50Hz Power 166 W Max Outlet Temp 1300 F 704 C Fuel Tank Capacity 15 L Ignition system...

Page 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 16: ......

Reviews: