Compressor
becomes too
hot.
Insufficient ventilation.
See that sufficient air is
supplied to flywheel or fan
of compressor and that
hot air is properly vented.
Oil level too low (check 2 or
3 minutes after stopping.
Fill with oil
Fault in valves (machine not
stopping).
Contact Clarke Service
Department
Blown head gasket (machine
not stopping).
Contact Clarke Service
Department
Dirt on cooling fins or suction
filter.
Clean cooling fins and
suction filter.
Unit working at too high a
pressure.
Contact Clarke Service
Department
Not fully unloading
Contact Clarke Service
Department
Load genie partly blocked.
Contact Clarke Service
Department
Compressor
unit runs on
and off load
more
frequently
than usual.
Large amount of
condensation in air receiver.
Drain off condensation
Regularly (Every day
before use).
Leaks in system
Locate leaks (by means of
soapy water) and repair.
Compressor
unit runs ‘on
load’ when
no air is being
used.
Leaks in system
Locate leaks (by means of
soapy water) and repair.
SYMPTOM
PROBABLE CAUSE
REMEDY