background image

3

Parts & Service: 020 8988 7400/E-mail:[email protected] or [email protected]

GENERAL SAFETY PRECAUTIONS

WARNING: This swimming pool pump is not a submersible pump. On
no account should it ever be immersed in water.

Always connect the pump to an earthed power supply via a RCD.

1.

ALWAYS 

keep the pump room clean and well lit. Floors should always be

kept clear. Cluttered or dark areas invite accidents.

2.

NEVER 

over-reach. Keep your proper footing and balance at all times

when installing or maintaining the pump.

3.

NEVER 

direct any water discharge towards electrical wiring or equipment.

4.

ALWAYS 

 thoroughly familiarise yourself with this pump & its operation, and

follow all  instructions in this manual.

 

Never allow persons unfamiliar with

these instructions to operate the pump.

5.

ALWAYS 

ensure that the pump is properly installed to prevent  it from

moving during operation, and that the immediate area surrounding the
pump is kept clear.

6.

ALWAYS

 maintain the pump with care and keep it clean for best / safest

performance.

7.

NEVER 

use this product if any part is damaged. Have it inspected and

repaired by your local Clarke dealer. Always turn the pump off before
carrying out any maintenance.

8.

NEVER 

modify this pump in any way. Use it ONLY for the purpose for which

it is designed.

9.

NEVER 

use for pumping flammable liquids or corrosive chemicals. This

pump is designed to pump clean water only.

10.

NEVER switch the pump ON when the pool is in use. ALWAYS disconnect
the pump from the electrical supply when the pool is in use.

11

.

This pump must be connected to an earthed power supply via a RCD.

12.

ALWAYS 

have the pump serviced by your local CLARKE dealer, using only

identical replacement parts. This will ensure the safety of the pump is
maintained. The use of non standard parts could be hazardous.

Your CLARKE water pump has been designed to give long and trouble free
service. If, however, having followed the instructions in this booklet carefully,
you encounter problems, take the unit to your local CLARKE dealer.

Please keep these instructions in a safe place for future reference.

Summary of Contents for SPP07

Page 1: ...OPERATING MAINTENANCE INSTRUCTIONS GC0514 SWIMMING POOL PUMPS Models SPP07 SPP10 SPP15 Part Nos 7175025 7175030 7175035 ...

Page 2: ...ion and the use of a non return valve will facilitate immediate priming The pump inlet is higher than the impeller inlet so that it can start operating when only the pump body is filled with water Upon receipt any damage or deficiency should be reported to your CLARKE dealer immediately CONTENTS 1 x Swimming Pool Pump c w integral Pre filter Basket 2 x Inlet Outlet Connectors 2 x Inlet Outlet Conn...

Page 3: ...pt clear 6 ALWAYS maintain the pump with care and keep it clean for best safest performance 7 NEVER use this product if any part is damaged Have it inspected and repaired by your local Clarke dealer Always turn the pump off before carrying out any maintenance 8 NEVER modify this pump in any way Use it ONLY for the purpose for which it is designed 9 NEVER use for pumping flammable liquids or corros...

Page 4: ...iring instructions shown below The old plug must be disposed of safely as insertion into a mains socket could cause an electrical hazard WARNING The wires in the power cable of this product are coloured in accordance with the following code Blue Neutral Brown Live Yellow Green Earth If the colours of the wires in the power cable of this product do not correspond with the terminal markings of your ...

Page 5: ...TION OF THE PUMP A typical installation of the pump is shown in Fig 1 The pump must always be installed and operated in a horizontal position i e with the outlet port facing vertically upwards The fixing holes in the base should be used to secure the pump firmly in it s operating position Mount the pump on raised blocks or a purpose built platform to protect it from flooding Always ensure there is...

Page 6: ...the use of suitable 50 mm I D hose secured with a worm drive clip Ensure all connections are air tight Tighten them enough to secure the hose during pressurised operation but not so tight as to crack the plastic inlet outlet connectors Where the pump is to be a permanent fixture vibration and strain on adjacent parts can be reduced by the insertion of a short flexible section of hose between any r...

Page 7: ...ming process and it is suggested that a non return valve be fitted to the end of the suction pipe 5 Stop the pump by switching off the power supply CARE DURING USE 1 Do not allow the pump to run dry otherwise the seal between the pump and motor may be damaged If a leak is noticed at this point it may indicate that the seal is worn and therefore in need of replacement Contact your CLARKE dealer or ...

Page 8: ...winter period or whenever there is danger of freezing always drain the pump body If the pump has been used with contaminated or salty water it should be thoroughly flushed with clean water following use both inside and out It should then be drained before replacing the drain plug and covered over if not already installed in a clean dry environment sheltered from the weather Remember to re prime th...

Page 9: ...k s a b r e t l i f n a e l c d n a k c e h C e d i s n i l a i r e t a m d e t s e g n o C p m u p t e k s a b r e t l i f t u o n a e l C p m u p h s u l f k c a b e n i l y r e v i l e d r o n o i t c u S d e t c u r t s b o e r u s n e d n a n o i t c u r t s b o e v o m e R e n i l y r e v i l e d n i s k n i k o n e r a e r e h t e g a k a e l e p i p t e l n I r o t c e n n o c d n a e p i ...

Page 10: ... p t e l n i n i e c n a t s i s e R y b d e s u a c n o i t c u r t s b o s a t u o n a e l c d n a e p i p k c e h C y r a s s e c e n t n e n o p m o c g n i t a t o r e s o o L r o f r e l a e d r u o y o t n r u t e R s r i a p e r s i p m u p f o n o i t a l l a t s n I e l b a t s n u n o i t i s o p e r d n a p m u p p o t S r o p m u p n i t e k c o p r i A e n i l e p i p r e l l e p m i...

Page 11: ... s e r P d n u o S A p L B d 1 2 6 A p L B d 8 2 6 A p L B d 2 6 6 l e v e L r e w o P d n u o S A w L B d 1 3 7 A w L B d 3 5 7 A w L B d 3 9 7 r e w o P d n u o S d e e t n a r a u G A w L B d 6 7 A w L B d 8 7 A w L B d 2 8 Please note that the details and specifications contained herein are correct at the time of going to print However CLARKE International reserve the right to change specifica...

Page 12: ... W 6 3 1 e g n a l F g n i t n u o M 1 4 4 k c o l B g n i t c e n n o C 6 4 1 r e h s a W 8 5 4 w e r c S e n i h c a M d H X 6 5 1 r e h s a W e v a W 2 1 6 4 x o B r o t i c a p a C 1 6 1 t l o B x e H 8 7 4 t e k s a G 1 7 1 d n a l G f o o r p r e t a W 1 8 4 r o t a t S r o t o M 1 8 1 t r o p p u S p m u P 1 9 4 g n i r a e B 2 9 1 t l o B d a e H t e k c o S 4 0 5 p i l c r i C 1 0 2 r e h...

Page 13: ...13 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM ...

Page 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Page 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Page 16: ...16 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Page 17: ...17 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Page 18: ...18 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Page 19: ...19 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Page 20: ......

Reviews: