RATING PLATE

DUTY CYCLE

This welder is covered by regulations EN60974-1 and EN 50199, where the Duty 
Cycle (X) is expressed as a percentage of time the machine may be used in a 
given period for a specified welding current.

i.e. When welding at 65 Amps the machine may be used for 6 minutes (60%) in 
any10 minute period, 

1

Name And Address Of Manufacturer

12

Rated Welding Current Symbol

2

Model Number, Part Number

13

Conventional Load Voltage Symbol 

3

Serial / Batch Number

14

Energy Supply Symbol

4

Welding Power Source

15

Rated Supply Voltage

5

British Standards Applied

16

Rated Maximum Supply Current

6

Welding Process Symbol

17

Maximum Effective Supply Current

7

This symbol indicates that the unit is 
suitable for carrying out welding 
operations in an environment which 
has an increased risk of electric 
shock.

18

N/a

8

Welding Current Symbol

19

N/a

9

Rated No-load Voltage

20

N/a

10

Range Of Output

21

N/a

11

Duty Cycle Symbol

22

Degree Of Protection

Summary of Contents for EASIARC 165

Page 1: ...Read these instructions before using the machine WARNING A suitable welding headshield must be worn during use OPERATION MAINTENANCE INSTRUCTIONS LS0413 160 AMP ARC WELDER MODEL NO EASIARC 165 PART NO...

Page 2: ...d against faulty manufacture for a period of 12 months from the date of purchase Please keep your receipt as proof of purchase This guarantee is invalid if the product is found to have been abused or...

Page 3: ...g part of the welding circuit FUMES GASES The welding process generates hazardous fumes as a by product Inhalation of these fumes is hazardous to health Keep your head away from the weld to avoid brea...

Page 4: ...e worn when others are working overhead Flammable hair sprays gels should not be used by persons intending to weld or cut PROTECTIVE CLOTHING Wear gauntlet gloves designed for use in welding Wear an a...

Page 5: ...traction in the work area as the welding process gives off toxic fumes ALWAYS ensure there is a fire extinguisher on hand ALWAYS ensure that a medical supply is on hand and that treatment for burns is...

Page 6: ...of this product do not correspond with the markings on the terminals of your plug proceed as follows The wire which is coloured Blue must be connected to the terminal which is marked N or coloured Bl...

Page 7: ...ediately The components include the following 1 x 160 Amp AC Arc Welder 1 x Combination Wire Brush Hammer 1 x Clarke Instruction Manual 1 x Face Shield OVERVIEW NO DESCRIPTION NO DESCRIPTION 1 Handle...

Page 8: ...s created from the flux within the welding rod electrode When using the welder outside you may need to take measures to erect a wind break to make sure the shielding gas is not blown away thereby leav...

Page 9: ...TH CLAMP Attach the earth clamp firmly to the workpiece as close as possible to the point of weld IMPORTANT Ensure that the earth clamp is attached to clean solid metal If necessary thoroughly clean w...

Page 10: ...should come unstuck with a sharp tug If it will not free easily turn off the welder immediately as it will quickly overheat then give the join a tap from the chipping hammer As you get more experience...

Page 11: ...heavy deposit which overlaps at the sides It is wasteful both in terms of time and electrode use ELECTRODE MOVED TOO QUICKLY This causes poor penetration with a stringy and incomplete weld deposit Sla...

Page 12: ...heres etc Always inspect the earth return and torch hose before use to ensure they are in perfect condition and that the earth clamp is clean and secured correctly to the cable As a general rule the p...

Page 13: ...Address Of Manufacturer 12 Rated Welding Current Symbol 2 Model Number Part Number 13 Conventional Load Voltage Symbol 3 Serial Batch Number 14 Energy Supply Symbol 4 Welding Power Source 15 Rated Su...

Page 14: ...me of the accessories available from your CLARKE dealer Please quote the part numbers shown below Model Easiarc165 Power Supply 230V 50Hz Rated Max Input Current I1Max I1eff 36 13 7 A Open Circuit Vol...

Page 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 16: ......

Reviews: