![background image](http://html.mh-extra.com/html/clarke/cdm45c/cdm45c_operating-instructions-manual_2614624012.webp)
12
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
DIRECT CURRENT
• Overload protection: F1 400mA/600V Fuse F2 10A/600V
• 10A range: F2, 10A/600V fuse (quick acting).
• Max input current:
• mA jack (mA range): 200 mA
• 10A jack: 10A
AC CURRENT
• Overload protection: mA ranges: reset table fuse F1, 400mA/600V dc
• 10A range:F2, 10 A/600V fuse
• Max input current: mA jack (mA range) 200mA
• 10A jack: 10A
• Frequency range: 40Hz to 400Hz
• Display: Average (effective value of sine wave)
CAPACITANCE
Range
Resolution
Accuracy
2mA
1µA
± 0.8% of reading, +1 digits
20mA
10µA
200mA
100µA
± 1.5% of reading, +1 digits
10A
10mA
± 2% of reading, + 5 digits
Range
Resolution
Accuracy
20mA
10µA
± 1% of reading, + 5 digits
200mA
100µA
± 1.8% of reading, + 5 digits
10A
10mA
± 3% of reading, + 7 digits
Range
Resolution
Accuracy
2nF
1µF
± 0.4% of reading, ±3 digits
20nF
10µF
200nF
0.1µF
20µF
1µF
± 0.4% of reading, ±2 digits
100µF
100µF
± 6.0% of reading, +10digits