Squeegee System
53
Service Manual – CA90 32T
Troubleshooting
Problem
Cause
Correction
Poor Water Pick-Up
Vacuum leak(s) due to:
• Leaky Vacuum hose
• Damaged pick-up adapter
gasket
• Drain plug not installed
properly
• Recovery tank cover is mis-
aligned, or damaged
• Damaged Tank
• Check the vacuum hose, and
tighten/replace as necessary
• Replace adapter gasket
• Insure drain hose plug is
installed correctly
•
Check the cover, and adjust/
replace as necessary
• Check the tank for leaks
Restrictions due to build up of
debris;
• In the recovery tank
• In the vacuum hose
• In the squeegee assembly
Check the recovery tank near
the opening for the pick-up
tube, check the vacuum hose,
and squeegee assembly for
accumulated dirt. Clean as
required.
Squeegee blades are worn, not
installed correctly, or out of
adjustment
Check the squeegee blades for
proper installation, wear, or
damage. Replace as required.
Flip the squeegee blade(s) to put
a new edge to the floor.
Adjust the squeegee blades and/
or angle.