Clarke Arc/Tig120 Operating & Maintenance Manual Download Page 5

5

take additional precautions such as filtering of the mains supply. Consideration
should be given to  shielding the supply cable of permanently installed welding
equipment, in metallic conduit or equivalent. Shielding should be electrically
continuous throughout its length. The shielding should be connected to the welding
power source so that good electrical contact is maintained between the conduit
and the welding power source enclosure.

2.2  Maintenance of the welding equipment

The welding equipment should be routinely maintained according to the
manufacturers recommendations. All access and service doors and covers should
be closed and properly fastened when the welding equipment is in operation.
The welding equipment should not be modified in any way except for those
changes and adjustments covered in the manufacturers

instructions. In particular, the spark gaps of arc striking and stabilizing devices should
be adjusted and maintained according to the manufacturers recommendations.

2.3  Welding cables

The welding cables should be kept as short as possible and should be positioned
close together, running at or close to the floor level.

2.4  Equipotential bonding

Bonding of all metallic components in the welding installation and adjacent to it
should be considered. However, metallic components bonded to the work piece
will increase the risk that the operator could receive a shock by touching these
metallic components and the electrodes at the same time. The operator should
be insulated from all such bonded metallic components.

2.5  Earthing of the workpiece

Where the workpiece is not bonded to earth for electrical safety, nor connected
to earth because of its size and position, e.g. ships hull or building steelwork, a
connection bonding the workpiece to earth may reduce emissions in some, but
not all instances.

Care should be taken to prevent the earthing of the workpiece increasing the risk
of injury to users, or damage to other electrical equipment.

Where necessary, the connection of the workpiece to earth should be made by
a direct connection to the workpiece, but in some countries where direct
connection is not permitted, the bonding should be achieved by suitable
capacitance, selected according to national regulations.

2.6  Screening and shielding

Selective screening and shielding of other cables and equipment in the surrounding
area may alleviate problems of interference. Screening of the entire welding
installation may be considered for special applications.

WIRING DIAGRAM

ARC/TIG90

ARC/TIG120

24

Summary of Contents for Arc/Tig120

Page 1: ...ARC TIG INVERTERS Model Nos Arc Tig90 Arc Tig120 Arc Tig150 ARC TIG INVERTERS OPERATING MAINTENANCE INSTRUCTIONS 0901...

Page 2: ...d value of the supply voltage nc Symbol for the number of reference electrodes capable of being melted with the welding power source starting from the cold state without operation of the thermal cut o...

Page 3: ...rantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purcha...

Page 4: ...alling welding equipment the user shall make an assessment of potential electromagnetic problems in the surrounding area Avoid using your inverter in the vicinity of a other supply cables control cabl...

Page 5: ...ial bonding Bonding of all metallic components in the welding installation and adjacent to it should be considered However metallic components bonded to the work piece will increase the risk that the...

Page 6: ...worn when others work overhead Flammable hair preparations should not be used by persons intending to weld or cut B Toxic fume prevention Severe discomfort illness or death can result from fumes vapo...

Page 7: ...ntainer that held combustibles or that can produce flammable or toxic vapours when heated must never be welded on or cut unless container has first been cleaned This includes a thorough steam or caust...

Page 8: ...the eyes should the helmet not be lowered over the face before an arc is struck Looking at an arc momentarily with unprotected eyes particularly a high intensity gas shielded arc can cause a retinal...

Page 9: ...l Electrical Code and the work is earthed a voltage may exist between the electrode and any conducting object Examples of conducting objects include but are not limited to buildings electrical tools w...

Page 10: ...breakers should not be disconnected or shunted out Before installation inspection or service of equipment shut OFF all power and remove line fuses or lock or red tag switches to prevent accidental tu...

Page 11: ...use the machine with any of the panels removed NEVER attempt any electrical or mechanical repair unless your are a qualified technician If you have a problem with the machine contact your local CLARKE...

Page 12: ...electrode about 10mm from the work and at an angle of about 70 to 80 to the work surface take care not to accidentally touch the workpiece until you are ready to commence 7 Holding the welding mask c...

Page 13: ...s sufficient electric current to melt both the electrode and a proper amount of base metal It also requires an appropriate gap between the tip of the electrodeandthebasemetalorthemoltenweldpool Theser...

Page 14: ...0 5mm without undue distortion Main Features of Tig Welding 1 Welds all metals 2 Electronic control of welding current 3 Forced air cooling 4 A Thermal Overload Protection Device prevents overheating...

Reviews: