When the Simpliport

®

 180 System is mounted in direct sunlight, the optic signal may be 

difficult to read or completely washed out by the intensity of the sunlight. Perform the 
following steps to improve the viewing of the water level in the gage glass. Note that the wide 
angle feature of the Simpliport 180 will no longer be available and the observer must look 
directly (horizontally) into the front hood to see the water level. 

 

1.  Using a Phillips screwdriver, remove the four screws (Item #5) from the Top End Cap (Item 

#2) and remove the cap. 

2.  Carefully slide out the Glass Shield (Item #10), the Optic Outputs (Item #7), and the Optic 

Output Plate (Item #9). Note: Black rubber spacer (not shown in detail below) on the bottom 
end cap under the Glass Shield must remain in place.  

3.  Set the Optic Outputs aside. 

4.  Insert the Glass Shield and Optic Output Plate back into the glass track in the Viewing Hood 

Extrusion (Item #6) with the Plate going in front of the Glass as shown in the illustration below. 

5.  Replace the Top End Cap, aligning the screw holes in the Cap with corresponding screw 

holes in the Side Panels (Item #3) and the Viewing Hood Extrusion. 

6.  Replace the four screws and tighten. 

7.

  The conversion is now complete and the  Front Hood can be installed back on to the 

Simpliport Gage Glass. 

                                              

 

Summary of Contents for Simpliport 180

Page 1: ...arkway Ɣ Strongsville OH 44149 USA Telephone 1 440 572 1500 Ɣ Fax 1 440 238 8828 www clark reliance com Ɣ sales clark reliance com Simpliport 180 Installation Operation Maintenance Instructions R500 E245A 03 04 2016 ...

Page 2: ... start up to ensure proper operation in the installed environment IMPORTANT Never remove the blue cord between the power supply and illuminator while power is applied Doing so will cause permanent damage to the LEDs Note All installation steps should be performed by a qualified technician and should be executed in accordance with all applicable national and local codes The LED Illuminator and powe...

Page 3: ...mmercial glass cleaners such as Windex or similar Never use harsh abrasives wire brushes metal scrapers or any material that could scratch the glass The Illuminator and viewing hood may be removed while in operation to inspect the Simpliport Gauge SPECIFICATIONS Power Supply 115 230 VAC 50 60 Hz Max Power Consumption 500 mA Est Life Up to 7 years continuous Agency Approvals FM CFM Ordinary Locatio...

Page 4: ...16633 Foltz Parkway Ɣ Strongsville OH 44149 USA Telephone 1 440 572 1500 Ɣ Fax 1 440 238 8828 www clark reliance com Ɣ sales clark reliance com ...

Page 5: ...elephone 1 440 572 1500 Fax 1 440 238 8828 www clark reliance com sales clark reliance com Removing Simpliport 180 Optic Outputs for Outdoor Viewing in Direct Sunlight Installation Operation Maintenance Instructions R500 E245A Supplement 08 31 2016 ...

Page 6: ...e four screws Item 5 from the Top End Cap Item 2 and remove the cap 2 Carefully slide out the Glass Shield Item 10 the Optic Outputs Item 7 and the Optic Output Plate Item 9 Note Black rubber spacer not shown in detail below on the bottom end cap under the Glass Shield must remain in place 3 Set the Optic Outputs aside 4 Insert the Glass Shield and Optic Output Plate back into the glass track in t...

Page 7: ...16633 Foltz Parkway Ɣ Strongsville OH 44149 USA Telephone 1 440 572 1500 Ɣ Fax 1 440 238 8828 www clark reliance com Ɣ sales clark reliance com Notes ...

Page 8: ...16633 Foltz Parkway Ɣ Strongsville OH 44149 USA Telephone 1 440 572 1500 Ɣ Fax 1 440 238 8828 www clark reliance com Ɣ sales clark reliance com ...

Reviews: