background image

16633 Foltz Parkway 

Ɣ

 Strongsville, OH  44149 USA   Telephone: +1 (440) 572-1500   

Ɣ

  Fax: +1 (440) 238-8828 

www.clark-reliance.com  

Ɣ

  [email protected]

The

Reliance

®

Simpliport

®

 180 LED Illuminator 

has been designed to accept 120VAC or 240 VAC 
power sources and for a service life of up to 7 years. 
The LED Illuminators are weatherproof and are 
rated safe for use in ordinary locations 

STORAGE and HANDLING 

All units should be inspected upon receipt to ensure 
that no damage has been incurred during transit.  If 
there is a claim due to damage, it should be filed 
with the carrier immediately.  Units should be stored 
in a dry and sheltered area prior to installation, in a 
secure manner where they can neither fall, nor be 
struck by other objects.  The temperature of the 
storage area should not exceed 170

q

 F. (75

q

 C.) 

COMPONENTS

There are five main components that make up the 
Simpliport Illuminator Assembly: the LED 
Illuminator, the front end hood, the mounting bar 
assembly, the power supply, and the cable 
connecting the power supply to the LED 
Illuminator.  The cable may have more than one 
piece depending on the required distance between 
the Illuminator and the power supply. In most cases, 
however, the power supply will be mounted directly 
to the LED Illuminator. 

INSTALLATION

CAUTION:  All LED Illuminators are 

tagged with the service conditions for that 
particular unit.  This information is located on 
the power supply housing.  The ratings should be 
reviewed prior to installation and again prior to 
start-up, to ensure proper operation in the 
installed environment.

IMPORTANT

Never remove the blue cord between the power 
supply and illuminator while power is applied.
Doing so will cause permanent damage to the 
LEDs.

Note:  All installation steps should be performed 
by a qualified technician and should be executed 
in accordance with all applicable national and 
local codes. 

The LED Illuminator and power supply should 

be checked to ensure that they contain no foreign 
matter, and that the end connections are clean, 
undamaged, and in line with existing conduit.   

Step by step instructions: 

1)

 

Assemble the mounting bar assemblies to the 
Simpliport Gage mounting lugs using the (4) 
5/16” X 1” SHCS that are provided (Fig. 1).

2)

 

To mount the LED Illuminator assembly to 
the gage:  While holding the illuminator at a 
slight angle, slide illuminator top onto pins.  
Align bottom pins with slots and rest unit in 
place.

Note: The Simpliport

®

 Gage must be 

viewed with the packing nuts facing 
slightly to the left. Make sure the 
Illuminator and viewing hood are in the 
correct orientation to the Simpliport

®

Gage.  (Fig. 2)

3)

 

Repeat the procedure in Step 2 to mount the 
front end hood to the opposite side (viewing 
side) of the gage. 

4)

 

The unit’s power supply has wire leads and a 
fuse ready to connect to the incoming AC 
power source.  Remove the enclosure lid to 
access wiring.  Connect incoming AC power 
source per local and National Electric Codes.
The fused (red) wire is to be connected is the 
“Hot” and the remaining white wire is the 
“common”. 

5)

 

The power supply can be remote mounted if 
desired.  After remote mounting of power 
supply, if the blue power cord will not reach 
the power supply, contact your local 
representative.

Summary of Contents for Simpliport 180

Page 1: ...arkway Ɣ Strongsville OH 44149 USA Telephone 1 440 572 1500 Ɣ Fax 1 440 238 8828 www clark reliance com Ɣ sales clark reliance com Simpliport 180 Installation Operation Maintenance Instructions R500 E245A 03 04 2016 ...

Page 2: ... start up to ensure proper operation in the installed environment IMPORTANT Never remove the blue cord between the power supply and illuminator while power is applied Doing so will cause permanent damage to the LEDs Note All installation steps should be performed by a qualified technician and should be executed in accordance with all applicable national and local codes The LED Illuminator and powe...

Page 3: ...mmercial glass cleaners such as Windex or similar Never use harsh abrasives wire brushes metal scrapers or any material that could scratch the glass The Illuminator and viewing hood may be removed while in operation to inspect the Simpliport Gauge SPECIFICATIONS Power Supply 115 230 VAC 50 60 Hz Max Power Consumption 500 mA Est Life Up to 7 years continuous Agency Approvals FM CFM Ordinary Locatio...

Page 4: ...16633 Foltz Parkway Ɣ Strongsville OH 44149 USA Telephone 1 440 572 1500 Ɣ Fax 1 440 238 8828 www clark reliance com Ɣ sales clark reliance com ...

Page 5: ...elephone 1 440 572 1500 Fax 1 440 238 8828 www clark reliance com sales clark reliance com Removing Simpliport 180 Optic Outputs for Outdoor Viewing in Direct Sunlight Installation Operation Maintenance Instructions R500 E245A Supplement 08 31 2016 ...

Page 6: ...e four screws Item 5 from the Top End Cap Item 2 and remove the cap 2 Carefully slide out the Glass Shield Item 10 the Optic Outputs Item 7 and the Optic Output Plate Item 9 Note Black rubber spacer not shown in detail below on the bottom end cap under the Glass Shield must remain in place 3 Set the Optic Outputs aside 4 Insert the Glass Shield and Optic Output Plate back into the glass track in t...

Page 7: ...16633 Foltz Parkway Ɣ Strongsville OH 44149 USA Telephone 1 440 572 1500 Ɣ Fax 1 440 238 8828 www clark reliance com Ɣ sales clark reliance com Notes ...

Page 8: ...16633 Foltz Parkway Ɣ Strongsville OH 44149 USA Telephone 1 440 572 1500 Ɣ Fax 1 440 238 8828 www clark reliance com Ɣ sales clark reliance com ...

Reviews: