background image

16633 Foltz Parkway 

Ɣ

 Strongsville, OH  44149 USA   Telephone: +1 (440) 572-1500   

Ɣ

  Fax: +1 (440) 238-8828 

www.clark-reliance.com  

Ɣ

  [email protected]

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

    

 

 

OPERATION

The Simpliport

®

 180 LED Illuminator can operate 

continuously.  The operating life of the LED’s is up to 
7 years under normal conditions. 

ROUTINE MAINTENANCE 

Keep glass on the front of the front end hood and in 
the illuminator assembly clean using commercial 
glass cleaners, such as Windex

®

 or similar.  Never 

use harsh abrasives, wire brushes, metal scrapers, or 
any material that could scratch the glass.  

The Illuminator and viewing hood may be removed 
while in operation to inspect the Simpliport

®

 Gauge. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPECIFICATIONS

 
 Power Supply:   

115/230 VAC @ 50-60 Hz 

 Max Power 

 

  

 Consumption:   

500 mA 

 Est. Life: 

 

Up to 7 years (continuous) 

 Agency Approvals: 

FM/CFM Ordinary Locations

 

 

 

 

 Wire Size: 

 

Min 16 AWG / Max 10 AWG 

 Max dist. from   

 

 power supply to light:  72’ (22 M)  

Standard Cable = 

8’ (2.5M) 

Ambient Temperature:  -40 F (-40 C) to 170 F (77C)

Viewing the Gauge 

Figure 1 

Figure 2 

Typical Installation 

Summary of Contents for Simpliport 180

Page 1: ...arkway Ɣ Strongsville OH 44149 USA Telephone 1 440 572 1500 Ɣ Fax 1 440 238 8828 www clark reliance com Ɣ sales clark reliance com Simpliport 180 Installation Operation Maintenance Instructions R500 E245A 03 04 2016 ...

Page 2: ... start up to ensure proper operation in the installed environment IMPORTANT Never remove the blue cord between the power supply and illuminator while power is applied Doing so will cause permanent damage to the LEDs Note All installation steps should be performed by a qualified technician and should be executed in accordance with all applicable national and local codes The LED Illuminator and powe...

Page 3: ...mmercial glass cleaners such as Windex or similar Never use harsh abrasives wire brushes metal scrapers or any material that could scratch the glass The Illuminator and viewing hood may be removed while in operation to inspect the Simpliport Gauge SPECIFICATIONS Power Supply 115 230 VAC 50 60 Hz Max Power Consumption 500 mA Est Life Up to 7 years continuous Agency Approvals FM CFM Ordinary Locatio...

Page 4: ...16633 Foltz Parkway Ɣ Strongsville OH 44149 USA Telephone 1 440 572 1500 Ɣ Fax 1 440 238 8828 www clark reliance com Ɣ sales clark reliance com ...

Page 5: ...elephone 1 440 572 1500 Fax 1 440 238 8828 www clark reliance com sales clark reliance com Removing Simpliport 180 Optic Outputs for Outdoor Viewing in Direct Sunlight Installation Operation Maintenance Instructions R500 E245A Supplement 08 31 2016 ...

Page 6: ...e four screws Item 5 from the Top End Cap Item 2 and remove the cap 2 Carefully slide out the Glass Shield Item 10 the Optic Outputs Item 7 and the Optic Output Plate Item 9 Note Black rubber spacer not shown in detail below on the bottom end cap under the Glass Shield must remain in place 3 Set the Optic Outputs aside 4 Insert the Glass Shield and Optic Output Plate back into the glass track in t...

Page 7: ...16633 Foltz Parkway Ɣ Strongsville OH 44149 USA Telephone 1 440 572 1500 Ɣ Fax 1 440 238 8828 www clark reliance com Ɣ sales clark reliance com Notes ...

Page 8: ...16633 Foltz Parkway Ɣ Strongsville OH 44149 USA Telephone 1 440 572 1500 Ɣ Fax 1 440 238 8828 www clark reliance com Ɣ sales clark reliance com ...

Reviews: