background image

http://www.xantrex.com

PN: 808-0817 / 808-0817-02

Freedom X Remote Panel User Guide

HAZARD OF FIRE, ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

This Freedom X Remote Panel User Guide is in addition to, and incorporates by reference, the 

relevant product manuals for each product in the Freedom X series. Before reviewing this guide 

you must read the relevant product manuals. Unless specified, information on safety, 

specifications, installation, and operation is as shown in the primary documentation received with 

the product. Ensure you are familiar with that information before proceeding.

Failure to follow these instructions will result in death or serious injury.

1

2

3

Exclusion for Documentation

UNLESS SPECIFICALLY AGREED TO IN WRITING, SELLER (A) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF 

ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION; (B) ASSUMES NO RESPONSIBILITY OR 

LIABILITY FOR LOSSES, DAMAGES, COSTS OR EXPENSES, WHETHER SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH 

MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER’S RISK; AND (C) 

REMINDS YOU THAT IF THIS MANUAL IS IN ANY LANGUAGE OTHER THAN ENGLISH, ALTHOUGH STEPS HAVE BEEN TAKEN TO MAINTAIN THE 

ACCURACY  OF  THE  TRANSLATION,  THE  ACCURACY  CANNOT  BE  GUARANTEED.  APPROVED  CONTENT  IS  CONTAINED  WITH  THE  ENGLISH 

LANGUAGE VERSION WHICH IS POSTED AT HTTP://WWW.XANTREX.COM.

Thank you for purchasing the Freedom X Remote Panel. This 

user guide will help you install and use the remote panel to 

operate and configure the Freedom X and XC series remotely.

Introduction

Check that you have the following items in the box before 

proceeding.

- the Freedom X remote panel unit

- user guide and mounting template

- 25-ft. 6-conductor cable kit (808-0817-02 unit only)

What’s In The Box

If you received the 808-0817 unit, you need to acquire 

one of the following 6-conductor cable kit from Xantrex. 

Go to http://www.xantrex.com/power-products-support to 

order.

• 25-ft. 6-conductor cable kit (PN: 31-6257-00)

• 50-ft. 6-conductor cable kit (PN: 31-6262-00)

What’s Required

Features

Status LED Indicators

LCD Screen

1. Prepare the remote panel unit and the 6-conductor 

com cable kit.

2. Choose a location for the remote panel unit within 

reach of the com cable and the inverter unit.

3. Use the mounting template (in section A) to make the 

installation of the remote panel easier.

4. Mount the remote panel unit.

5. If you have a Freedom 458 unit, you may use it with 

the Freedom X Remote Panel. Installation 

instructions are available in section B.

Installation

976-0367-01-01 Rev D

09-2019

Copyright © 2018 Xantrex LLC. All Rights Reserved. 

All trademarks are owned by Xantrex LLC or its affiliated companies. Other trademarks are

owned by their respective companies.

page 1

LCD

screen

OUTPUTBATTLOAD

kW

100%

25%

Hz

VA

%

kW

Hz

VA

%C

INPUTBATTTEMP

AC

BYPASS

ERROR

OVERLOAD

CHARGING







Status LED 

indicators

Power 

button

ESC button
Scroll 

button

OK button

Function buttons

Indicates grid mode in which shore power is available 

and passing through to the loads and charging the 

battery.

Indicates battery mode (inverter mode) in which the 

inverter is running and supplying power to the loads from 

the battery.

Indicates error or fault mode and is accompanied by an 

error code displayed on the LCD screen.

Indicates a warning condition and is accompanied by an 

error code and a sounding alarm.

solid green

solid green

solid red

flashing red

AC





ERROR



OVERLOAD

AC input and output indicator.

The wrench icon underneath a number is displayed 

during configuration mode.

An error event with its corresponding number is 

displayed here.

A warning event with its corresponding number is 

displayed here.

The battery icon indicates remaining battery power. 

One bar = 1-25%, two bars = 25-50%, three bars = 

50-75%, and four bars = 75-100%.
Shows an AC output overload condition.

The load icon is displayed if there is voltage available at 

the AC output.

FCC/IC Information to the User

This device complies with Part 15 of the FCC Rules/Canada Industry licence-exempt RSS standard(s). Operation is subject to the 

following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, 

including interference that may cause undesired operation.

NOTE

: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC 

Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This 

equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may 

cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular 

installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the 

equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and the receiver.

• Connect the equipment to a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

WARNING

: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to 

operate the equipment.

RF Exposure

: The equipment has been evaluated to meet general RF exposure requirement. The device can be used in portable 

condition without restriction.

FCC ID: 2AODL-FXRP-BT / IC: 23407-FXRPBT

Function Buttons

return to default screen or exit setting mode
next screen or next selection
to enter the setting mode or to confirm the setting

turns the inverter unit on or standby

NOTE

: Only when the inverter’s Power button is off

NOTE

: Briefly pressing any function button activates backlight illumination. After 60 

seconds of inactivity, backlight illumination turns off.

808-0817-02 only

C

M

Y

CM

MY

CY

CMY

K

976-0367-01-01_Rev-D(artwork).pdf   1   9/25/2019   4:40:56 PM

Reviews: