6. REMOVING THE MAIN UNIT
1. When the rear of the main unit has been
secured with the method shown in Figure 6
unfasten the special screw.
2. Remove the outer escutcheon.
3. Insert the hook plate between the spring and
the universal mounting bracket, fit tab
B
of
the spring into hole
A
of the hook plate, then
pull the main unit out by the hook plate. (Insert
both the right and left edges of the hook
plate.) (Figure 9)
Note:
•
Keep the hook plate. You cannot remove the main
unit without disengaging the hook plate.
7. CAUTIONS ON WIRING
1. Be sure to turn the power off before wiring.
2. Be particularly careful where you route the
wires.
Keep them well away from the engine, and
exhaust pipe, etc. Heat may damage the
wires.
3. If the fuse should blow, check to see if the
wiring is correct.
If a fuse is blown, replace it with a new one of
the same amperage rating as the original
(15A FUSE).
4. To replace the fuse, remove the old fuse of
the power supply lead and insert the new one.
(Figure10)
Note:
•
There are various types of fuse holder. Do not let
the battery side touch other metal parts.
CAUTION
caution
After the connection, fix the lead by a clamp
or insulation tape for protection.
Universal mounting bracket
2-Hook plate
Outer escutcheon
Instrument panel
Spring
Main
Unit
A
B
Figure 9
Fuse (15A FUSE)
Fuse holder
Figure 10