29
CLAGE
EN
Long period of non-use
Note: In ambient / warm water germs can multiply faster. Therefore, leave your
drinking water system switched on even during long periods of non-use.
If you still want to shut down your drinking water system for an extended period of
time, proceed as follows:
1. Turn off the water supply.
2. Tap chilled and sparkling water until no more water flows to empty the system.
3. Close the CO
2
supply.
4. Switch off the appliance and disconnect the power supply.
After prolonged non-use
1. Reconnect the water supply. Pay attention to any leaks.
2. Reconnect the appliance to the power supply and switch it on.
3. Open the CO
2
supply
4. After non-use of several days: Start the CO
2
-flush (see chapter 5 “Menu”,
subpoint “Install”) and subsequently drain at least 2 litres of cold water from
the fitting.
If necessary collect the water in a suitable container.
5. The appliance is now ready for use.
Note: If the system is not used for more than two months, the internal filter must
be replaced even if the change interval has not been reached!
Natural traces
The activated carbon contained in the filter is subject to natural fluctuations. By e.g.
vibrations during transport can result in slight abrasion of small coal particles. These
particles are harmless to health. If you see particles in the water, follow the instructions
in chapter 6 ”Filter Replacement” sub point 7.
ambient light.
• The time switch reduces the energy demand according to the time set. The date and
time must be correctly set on the unit for this to operate correctly.
Dispensing time – pull / turn the lever on the tap forward and set the dispensing time.
5. Using the Tap