4. Installation
Installing the undersink unit
Note: An air gap of at least 50 mm at the left and right of the unit must be
provided for adequate ventilation. If the unit is to be operated inside a cupboard,
the supplied silicone buffers should be affixed to the inside edge of the cupboard
doors and the ventilation grills should be installed.
Optional the ventilation grills should be installed, if the temperature rises above
35 °C in the cupboard.
Please note the installation drawing below:
=
=
max 43
314.00
12.00
12.00
285.00
12.00
5
326.00
A
60.00
B
C
12.00
45.00
28
4
A
B
C
Note: If you using the vent tray kit KXB
see chapter ‘Installation with KXB’ for
attaching the venting cut outs.
The cut outs A and B can be covered with
the provided ventilation grilles.
The provided ventilation shaft has to be
mounted on the device and placed in the
cut out C. It will lead the warm air under
the cupboard floor, from where it can
escape through cut out A. To be able to
position the ventilation shaft over cut out
C, the cut out must be placed minimum
85 mm in front of the back plate, min.
10 mm from the left side wall and min.
115 mm to the front cover.
There must be a distance from at least
10 cm between the cut outs A and B, to
avoid a thermal short circuit.
O-Ring
Rubber
seal
Socket
Nut
Locking
washer
Triple silicone tube
Cold water
+ sparkling
water
Steam
empty
Herbie hose clamp
20 mm
Install hose set
1. Slide the Herbie hose clamp from below onto the triple-silicone tube.
Do not close the clamp yet!
2. Connect the blue and white plastic tubing to the quick connectors of the chilled and
sparkling connector and push the flattened side of the connector approx. 20 mm
into one of the side openings of the triple silicone tube.
The flat surface must be aligned to the middle.
3. Push the flattened side of the empty connector approximately 20 mm into the other
side opening of the triple silicone tube.
The flat surface must be aligned to the middle.
4. Position the Herbie hose clamp as close as possible to the end of the triple silicone
tube and close it by pressing with a pair of pliers.
Note: For maximum grip on all three connectors, ensure the Herbie hose clamp is
aligned axial to the silicone tube.
plate with the fastening nut. Check the tap head is in the correct position before
tightening up the nut.
Pay attention to the correct position of the O-ring at the socket.