Zip HydroTap® G4 CS175
28
EN
5. Using the Tap
Blue light
• On all the time: temperature of chilled water is at the set temperature.
• Flashing: the water has not yet been chilled to the set temperature.
White light (Arc)
• On all the time: temperature of sparkling water is at the set temperature.
• Flashing: the water has not yet been chilled to the set temperature.
White filter LED (Classic)
• Flashing: the filter needs to be replaced. This LED starts flashing according to filter
use and the filter capacity set in the menu.
Note: For the taps Arc and Celsius Arc the need for a filter replacement is indi-
cated by cyclically flashing all the LEDs in all three colours
Menu
The undersink unit has a touch screen which can be used to set and read the operating
parameters. The following settings can be carried out in the menu:
‘Language’
Select the language used in the menu.
‘Information’
Shows data specific to the unit and any errors occurring.
‘Install’
The steps that are necessary when using the unit for the first time can be viewed again
for maintenance purposes.
Flush filter – place the end of the hose located at the filter in a collecting container and
open the isolating valve on the hose before starting to flush the filter.
Reset filter – resets the filter consumption data.
CO
2
flush – air and water inside the carbonizer are flushed out with carbon dioxide to
ensure that the carbonizer operates correctly. Wait about 10 seconds and then touch
‘Stop’ to stop CO
2
flushing.
Light sensor calibration – the light sensor on the Classic tap can be calibrated for the
light conditions at the installation location. This is necessary to ensure that the Sleep
mode energy-saving function operates correctly. Shield the tap from direct sunlight
during calibration.
‘Service’
A special password specific to the unit is needed in order to access the Service menu.
Please contact Central Customer Service.
‘Password’
A user password can optionally be set to lock the ‘Settings’ menu and prevent
unauthorised persons from altering the settings. The password should be 4 digits long.
‘Radio’
N/A.
‘Settings’
Date/time – set the time and the time format.
Filter – enter the filter data in order to calculate the remaining filter capacity.
Energy saving – the unit’s chilling function can be disabled when the unit is not in use,
to reduce the energy demand.
• Sleep mode automatically reduces the energy demand according to use or to the