CLAGE
5. Initial operation
23
Double Power
Depending on the home installation, the following connection variations are possible:
• Variant A, (fig. 12.2)
If no low-tariff electricity is to be used, do not remove bridge between L1 and L1T.
• Variant B, (fig. 13)
Connect the output of the autotimer (delivered by the electricity provider) with L1 and L1T.
• Variant C, (fig. 14)
Connect switched phase L1T (connection for low-tariff power) to L1T terminal.
• Variant D, (fig. 15)
Connect switched phase L1 to terminal L1 and L1T.
Refer to the connection types recommended for double power (page VI fig. 12.2)
According to the duration of the off-peak period of either 8 or 4 hours, and the associated loads
(refer to connection types on page VI), set the power switch “S1” to the correct positions, 5 /6 / 7,
of the double power set-up.
Single Power
Depending on the home installation, the following connection variations are possible:
Refer to the connection types recommended for single power (page V fig 12.1)
Set power switch “S1” on the electronic board to positions 1 / 2 / 3 / 4 “single power”.
Boiler
Depending on the home installation, the following connection variations are possible: Refer to the connection types
recommended for boiler switch (page V fig. 12.1) Set power switch “S1” on the electronic board to positions 8 / 9 / 0
“Boiler mode”.
Finally, separate the appropriate circuit fig. (E1/E2/E3/E4) and the corresponding power-switch position “S1” from the
enclosed adhesive foil and adhere to the pad provided. Fill out the information decal about the installed circuit and
installed load and adhere to the outside of the cover.
Initial Use
1. Fill the reservoir and flush it out until water discharges from all hot water taps bubble free, otherwise the tempera-
ture sensor and retainer will be damaged and require replacing.
2. Check all water connections for leaking water.
3. Switch on the power supply to the appliance.
4. Press the “ON/OFF”-button (fig. 1; ref. A).
5. During heating, displaced water must drop from the discharge of the safety valve (closed operation) or out of the
mixer tap (open operation). Monitor the first heating cycle.
Temperature Limit (fig. 11)
Set the temperature limiter (40/60 or 85 °C) by the selector on PCB board. The appliance is factory-set at the position
85 °C.
Danger of electric shock!
The power switch “S1” may only be operated in an unpowered condition!!
Summary of Contents for SX 100
Page 28: ...SX50 SX80 SX100 SX120 II 3 Dimensionen Dimensions 4A...
Page 29: ...CLAGE III 4B 5 6 MOD 120 MOD 50 80 100 C...
Page 30: ...SX50 SX80 SX100 SX120 IV 7 8 10 11 9...
Page 31: ...CLAGE V 12 1 Anschlussarten Einkreis Boiler Betrieb Single power and boiler connection...
Page 32: ...SX50 SX80 SX100 SX120 VI 12 2 Anschlussarten Zweikreis Double power connection...