CLAGE
Display (LED)
Status
Panel LED
Cause/
Failure
Solution
Who
1
2
3
4
5
6
7
8
9
blinking
off
off
on
on
See below
(*)
-
on
on
Internal elec-
tronic fault
Electronic board locked,
wait 15mins and then reset;
if the problem remains
please contact technician
Customer/
Technician
blinking
off
off
on
-
See below
(*)
-
-
-
Temperature
sensor fault
Reset, if the problem
remains please contact
after sales service
Technician
blinking
off
off
on
on
See below
(*)
-
-
-
Temperature
fault between
heating/sensor
blinking
off
off
on
-
See below
(*)
-
on
-
Water tempe-
rature in reser-
voir too hot
blinking
off
off
on
-
See below
(*)
-
-
on
The reservoir
has heated
without water
8. Trouble-shooting and service
25
3
4
2
5
7
8
9
6
1
C
A
B
If your device does not function as intended, it is usually due to a small detail. Please check whether or not the fault
can be self-repaired according to the following indicators. You will thereby avoid the costs of an unnecessary repair
service. In normal operations, the LED “ON/OFF” is constantly lit. If LED “ON/OFF” is blinking, this indicates an “error
condition”.
In case of fault, do not disconnect the power supply line. In order to possibly remedy the error condition oneself, try to
reset the product as reference procedure:
RESET:
If an error condition occurs reset the appliance by pressing the ON/OFF button until the appliance turn off.
Then press the ON / OFF button again to turn it back on.
If the cause of the error condition does not exist directly after the reset, the device will return to its normal mode of
function. Otherwise the device will again indicate an “error condition”.
Diagnostic routines
In order to better define the error condition, the device uses diagnostic routines. Please activate the program as follows:
1. Push and hold the button “FAST” for at least 5 seconds.
2. The type of fault will now be displayed by the panel LEDs (1-9), as presented in the following table:
Summary of Contents for SX 100
Page 28: ...SX50 SX80 SX100 SX120 II 3 Dimensionen Dimensions 4A...
Page 29: ...CLAGE III 4B 5 6 MOD 120 MOD 50 80 100 C...
Page 30: ...SX50 SX80 SX100 SX120 IV 7 8 10 11 9...
Page 31: ...CLAGE V 12 1 Anschlussarten Einkreis Boiler Betrieb Single power and boiler connection...
Page 32: ...SX50 SX80 SX100 SX120 VI 12 2 Anschlussarten Zweikreis Double power connection...