background image

Page

 

10

  

WS1CS & WS1.25CS Manual

 4 

Reserve capacity estimate is based on history of water usage.

Setting Options Table

Volume

Capacity

Regeneration 

Time Option

Day 

Override

Result

4

AUTO

NORMAL

oFF

Reserve capacity automatically estimated.
Regeneration occurs when volume capacity falls below the reserve 
capacity at the next Regen Set Time

AUTO

NORMAL

Any 

number

Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when volume capacity 
falls below the reserve capacity or the speci

fi

 ed number of days between 

regenerations is reached.

Any 

number

NORMAL

oFF

Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when volume 
capacity reaches 0.

oFF

NORMAL

Any 

number

Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the speci

fi

 ed 

number of days between regenerations is reached.

Any 

number

NORMAL

Any 

number

Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when volume 
capacity reaches 0 or the speci

fi

 ed number of days between 

regenerations is reached.

AUTO

On 0

oFF

Reserve capacity not automatically estimated.
Regeneration occurs immediately when volume capacity reaches 0. 
Time of regeneration will not be allowed to be set because regeneration 
will always occur when volume capacity reaches 0.

Any 

number

On 0

oFF

Reserve capacity not automatically estimated.
Regeneration occurs immediately when volume capacity reaches 0. 
Time of regeneration will not be allowed to be set because regeneration 
will always occur on 0.

AUTO

on 0

oFF

Reserve capacity automatically estimated.
Regeneration occurs when volume capacity falls below the reserve 
capacity at the next Regen Set Time or regeneration occurs after 10 
minutes of no water usage when volume capacity reaches 0.

AUTO

on 0

Any 

number

Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when volume capacity 
falls below the reserve capacity or the speci

fi

 ed number of days between 

regenerations is reached or regeneration occurs after 10 minutes of no 
water usage when volume capacity reaches 0.

Any 

number

on 0

Any 

number

Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the speci

fi

 ed 

number of days between regenerations is reached or regeneration occurs 
after 10 minutes of no water usage when volume capacity reaches 0.

Filters should only use shaded options

Summary of Contents for Water Specialist WS1.25CS

Page 1: ...Valve Series Model WS1 25CS Operation and Instruction Manual for OEM Only Please Note This operation and instruction manual is for the training of the OEM and for the OEM to use to train their custome...

Page 2: ......

Page 3: ...System Setup 9 Setting Options Table 10 OEM Filter System Setup 11 Installer Display Settings 12 User Displays Settings 12 Diagnostics 14 Valve History 15 CS Front Cover and Drive Assembly 16 FOR INFO...

Page 4: ...the market Control valve installation is made easy because the distributor tube can be cut above to below the top of tank thread The distributor tube is held in place by an o ring seal and the contro...

Page 5: ...he following page should be used only as a guideline Any program code listed can be applied to a softener or filter application for WS1CS valves Program Code Main Piston 1st Backwash Brine Slow Rinse...

Page 6: ...e Backwash 2nd Cycle Regenerate 3rd Cycle Second Backwash 4th Cycle Rinse 5th Cycle Fill 6th Cycle Service 1st Cycle Fill 2nd Cycle Service 3rd Cycle Backwash 4th Cycle Regenerate 5th Cycle Second Bac...

Page 7: ...en the gallon capacity reaches zero 2 Pressing and holding REGEN for approximately 3 seconds will immediately start the regeneration The user cannot cancel this request except by resetting the control...

Page 8: ...urns to a normal user display Any changes made prior to the five minute time out are incorporated The one exception is current flow rate display under the diagnostic procedure The current flow rate di...

Page 9: ...the ion exchange capacity in grains of hardness as calcium carbonate for the system based on test data using or Press NEXT to go to Step 6S Press REGEN to return to previous step STEP 6S Enter the po...

Page 10: ...ity not automatically estimated Regeneration occurs immediately when volume capacity reaches 0 Time of regeneration will not be allowed to be set because regeneration will always occur when volume cap...

Page 11: ...e being used and that the injector or injector plug s are in the correct locations See Compliance Table in WS1 and WS1 25 Drawings and Service Manual Press NEXT to go to Step 5F Press REGEN to return...

Page 12: ...w REGEN on 0 GAL if on 0 is selected in Step 8S or Step 7F Press NEXT to go to step 5I Press REGEN to return to previous step STEP 5I Next Regeneration Time minutes Set the minutes of day for regenera...

Page 13: ...ds The system will begin to regenerate immediately The request cannot be cancelled Note For softeners if brine tank does not contain salt fill with salt and wait at least two hours before regenerating...

Page 14: ...This display will show dashes if a water meter is not installed Press NEXT at any time to go to Step 6D Press REGEN to return to previous step STEP 6D Flow rate current Turn the water on at one or mor...

Page 15: ...as occurred since startup This display will equal zero if a water meter is not installed Press NEXT to go to Step 4VH Press REGEN to return to previous step STEP 4VH Gallons total used since start up...

Page 16: ...ING CLIP 1 Not Shown V3186 05 WS1 POWER SUPPLY 15VDC VI 1 CS Front Cover and Drive Assembly Battery Fully Seated When replacing the battery align positives and push down to fully seat Correct Battery...

Page 17: ...WS1CS WS1 25CS Manual Page 17...

Page 18: ...Page 18 WS1CS WS1 25CS Manual...

Page 19: ...WS1CS WS1 25CS Manual Page 19...

Page 20: ...2017 Revision History U S Patents 6 402 944 6 444 127 6 776 901 1 27 2017 PAGE 16 Drawing number parts 2 3 5 and 6 may be purchased as a complete assembly part V3002 PAGE 4 Updates to table and drawi...

Reviews: