background image

9

2.  Use a battery powered or properly grounded 

drill. Using the Clamp port as a drill guide,  

drill a 

7

/

32

" hole through the wall of the drain 

pipe. Do NOT penetrate the opposite side of 

the pipe. 

3.  Locate the 

3

/

8

" Black Drain Tubing connected 

to the Dispensing Faucet. Route the tubing to 

the Drain Clamp and trim to length. 

  NOTE: When cutting the polytubing make  

clean, square cuts, failing to do so could 

result in poor connections and possible 

leaks. 

  NOTE: The lowest point of the line should be 

the point of connection to the Drain Clamp. 

There should be no sag in the line as this 

may cause excessive noise as the reject 

water is flowing to drain.

  Route the tubing to the Drain Clamp and 

trim to length. Insert the tubing into the Drain 

Clamp. Make sure the tubing is pressed all 

the way in. 

D.  R.O. Manifold Assembly Installation 
  Various installation sites will require different 

types of mounting fasteners; be sure the 

fastener selected will provide a firm, solid 

mounting. A support panel may be necessary on 

thin cabinet walls or to span between wall studs 

on particleboard or drywall. 

  Do not drill through exterior cabinet walls or 

leave sharp wood screw points exposed in 

readily accessible cabinet interiors. 

  The close proximity of a dishwasher or a trash 

compactor may require special fabrication of a 

mounting plate. 
1.  The mounting bracket will accept either #10 

or #12 (5mm) mounting screws spaced on 

6" (15 cm) centers. Allow at least 4" (10 cm) 

of clearance beneath the filter housings to 

accommodate filter changes. Mark the two 

locations (the bracket can be used as a 

template). Install the screws and tighten them 

until the heads are about 

5

/

8

" from the wall.

RED

BLACK

YELLOW

IN

DRAIN

OUT

DRAIN 

RESTRICT

OR

2.  Locate the ¼" Red Feed Water Tubing. 

Remove the red plug from the fitting labeled 

“In” on the manifold and insert the tubing. 

Reference the special supplement sheet in 

the carton for proper connection of all tubing 

and removal of plugs. Run the tubing along 

its course to the Feed Water Saddle Valve, 

trim to length. (Refer to Fig. 1.) 

  Refer to Fig. 3. To the end of the red polytube 

install the Compression Nut, the Plastic 

Ferrule, and the Insert. Connect to the Feed 

Water Saddle Valve.

3.  Locate the ¼" Black Drain Tubing connected 

to the Dispensing Faucet. Remove the black 

plug from the fitting labeled “Drain” on the 

manifold. The end of the Black Drain Tubing 

that should be inserted into the “Drain” port 

will have a drain restrictor in it.

4.  Locate the ¼" yellow tubing with the tee 

attached to one end. Remove the yellow plug 

from the fitting labeled "Out" on the manifold 

and insert the tubing.

5.  Locate the 

3

/

8

" Blue Product Water Tubing 

connected to the faucet. Firmly press one 

end into the tee. (Refer to Fig. 1.) The fitting 

will grab the tubing and seal it in place. Make 

sure the tubing is pressed all the way in to 

create a pressure tight connection. 

6.  Hang the Manifold Assembly on the 

mounting screws and tighten. DO NOT 

OVERTIGHTEN.

7.  Remove the wrapping from the  

In–Line Activated Carbon Post Filter. Slice 

the 

3

/

8

" Blue Polytube where it would be 

convenient to install and change the In–Line 

Filter. Make a clean straight cut to insure 

proper connections. The “Out” port on the  

In–Line Filter should be towards the faucet. 

Firmly press in the tubing. The fittings will 

grab the tubing and hold and seal it in place. 

Make sure the tubing is pressed all the way 

in to create a pressure tight connection.

Summary of Contents for T.F.C.-400

Page 1: ...components critical for effective performance It is the user s responsibility to and the manufacturer strongly recommends that the user periodically test the product water to verify the system is per...

Page 2: ...8 C Drain Clamp Installation 8 D R O Manifold Assembly Installation 9 E Position the Drinking Water Holding Tank and Make the Final Hose Connections 10 F Start Up 10 SECTION IV OPERATION AND MAINTENAN...

Page 3: ...cess dissolved minerals are separated from the incoming water Feed Water to produce the product water the Permeate The excess minerals are rinsed to drain the Reject Water The membrane is a specially...

Page 4: ...king water holding tank mount holding tank on shelf or strap between floor joists shelf or straps not included activated carbon pREfilter housing Reverse osmosis membrane housing sediment prefilter ho...

Page 5: ...hours The production rate of a new Membrane can decrease by 10 per year or more depending upon the scaling and fouling tendencies of the Feed Water TABLE B RECOMMENDED OPERATING LIMITS FOR FEED WATER...

Page 6: ...ller drill as a pilot and then drill a diameter hole to accept the bolt of a 1 Greenlee Hole Punch 1 chassis punch Clean away any chips Install the punch and tighten the nut to cut the hole Deburr any...

Page 7: ...OLYTUBE TO DRAIN PORT ON RO SYSTEM BLUE 3 8 POLYTUBE PRODUCT OUTLET 5 Connect the tubing to the Faucet Push the Blue 3 8 Polytube into the 3 8 Quick Connect Fitting Push the Black 3 8 Polytube onto th...

Page 8: ...til it is fully pierced When you feel the Valve Handle firmly seated in the clockwise direction the copper tube is pierced and the valve is closed 2b To install on hard Steel or Brass Tubing supply li...

Page 9: ...and tighten them until the heads are about 5 8 from the wall RED BLACK YELLOW IN DRAIN OUT DRAIN RESTRICTOR 2 Locate the Red Feed Water Tubing Remove the red plug from the fitting labeled In on the ma...

Page 10: ...nd install prefilter O rings up toward manifold Insert a Housing O ring into the Housing groove press firmly in place Engage and firmly tighten the Housing hand tight only Remove the plugs labeled ACT...

Page 11: ...ood idea to resanitize the system and to change the prefilter and post filters B Changing Filters THIS R O SYSTEM CONTAINS FILTERS WHICH MUST BE REPLACED AT REGULAR INTERVALS TO MAINTAIN PROPER PERFOR...

Page 12: ...st 8 hours Discard the first three full tanks of water produced they will contain chlorine IN LINE ACTIVATED CARBON POST FILTER ASSEMBLY OUT IN In Line Activated Carbon Post Filter 3 8 Blue To Dispens...

Page 13: ...13 NOTES...

Page 14: ...14 NOTES...

Page 15: ...15 NOTES...

Page 16: ...eck The ASO Valve is malfunctioning Replace ASO Valve components Low pressure at the Dispensing Faucet In Line Activated Carbon Post Filter is plugged Replace Post Filter Air precharge in the Holding...

Page 17: ...r in the Holding Tank Clean flush and sanitize the system Replace the filters The Product Water and Drain Water lines are reversed Correct plumbing Dissolved gasses in the Feed Water Pretreat Feed Wat...

Page 18: ...18 MADE IN USA 15 Exploded View Parts List 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 18 17...

Page 19: ...S7028 Activated Carbon Prefilter 13 S3069 Housing O Ring 14 S7029 09 Housing 15 S2116 5 Drain Restrictor 50 GPD 189 lpd 16 S1764RS T F C RO Membrane 50 gpd 189 lpd 17 S1405 1 4 3 8 Fitting Wrench 18...

Page 20: ...harges You must also pay for shipping or travel charges to return the defective part s What Does This Warranty Not Cover This warranty does not cover the disposable sediment and carbon filters whose s...

Reviews: