SECTION V. TROUBLE SHOOTING GUIDE

Problem

Possible Cause

Solution

Low quantity of Product Water  

from Holding Tank

Feed Water Saddle Valve is plugged or 

closed.

Open Valve or unclog.

Clogged Sediment Prefilter or Activated 

Carbon Prefilter.

Replace filters.

Low water pressure

Feed Water pressure must be above 

40 psig.

R.O. Membrane is fouled.

See Feed Water operating limits. 

Correct cause of fouling, replace 

Membrane.

Plugged In–Line Activated Carbon 

Post Filter.

Replace Post Filter.

Air precharge pressure in Holding Tank 

is too high.

Empty water from Holding Tank, 

and with the faucet open, adjust air   

pressure to 5–7 psig (35–48 kPa) range.

Air precharge is too low.

Air bladder in the Holding Tank is   

ruptured.

Replace tank.

Holding Tank Valve is closed.

Open Valve.

No drain flow, the Drain Restrictor is 

plugged.

Clear or replace Drain Restrictor.

No drain flow, the drain orifice in the 

Dispensing Faucet is plugged.

Clear or replace the Dispensing Faucet.

The Check Valve is stuck.

Free check.

The ASO Valve is malfunctioning.

Replace ASO Valve components.

Low pressure at the Dispensing 

Faucet

In-Line Activated Carbon Post Filter  

is plugged.

Replace Post Filter.

Air precharge in the Holding Tank is   

too low.

Empty water from Holding Tank and 

with the faucet open, adjust the air 

pressure to 5–7 psig (35–48 kPa) range.

Check for leakage at the Air Valve 

Stem.

Holding Tank Valve is partially closed.

Open Valve. 

The Dispensing Faucet is out of 

adjustment or faulty.

Repair or replace Dispensing Faucet.

Heavy water use, Holding Tank is 

depleted.

Allow Holding Tank to refill (adding a 

second Holding Tank will increase  

storage capacity).

Low Water Production.

See Low Quantity of Product Water  

from Holding Tank section above

High Total Dissolved Solids (TDS) in 

the Product Water

Clogged Sediment Prefilter or Activated 

Carbon Prefilter.

Replace Filters.

Low Water Pressure.

Feed Water Pressure must be above  

40 psig.
Check Feed Water Saddle Valve.

R.O. Membrane O–ring is crimped.

Check O–ring.

R.O. Membrane brine seal is not 

sealing up into the manifold head.

Check the brine seal.

R.O. Membrane is expended.

 If Membrane life is unusually short, 

 find and correct the problem.  

 Replace Membrane.

Summary of Contents for T.F.C.-400

Page 1: ...components critical for effective performance It is the user s responsibility to and the manufacturer strongly recommends that the user periodically test the product water to verify the system is per...

Page 2: ...8 C Drain Clamp Installation 8 D R O Manifold Assembly Installation 9 E Position the Drinking Water Holding Tank and Make the Final Hose Connections 10 F Start Up 10 SECTION IV OPERATION AND MAINTENAN...

Page 3: ...cess dissolved minerals are separated from the incoming water Feed Water to produce the product water the Permeate The excess minerals are rinsed to drain the Reject Water The membrane is a specially...

Page 4: ...king water holding tank mount holding tank on shelf or strap between floor joists shelf or straps not included activated carbon pREfilter housing Reverse osmosis membrane housing sediment prefilter ho...

Page 5: ...hours The production rate of a new Membrane can decrease by 10 per year or more depending upon the scaling and fouling tendencies of the Feed Water TABLE B RECOMMENDED OPERATING LIMITS FOR FEED WATER...

Page 6: ...ller drill as a pilot and then drill a diameter hole to accept the bolt of a 1 Greenlee Hole Punch 1 chassis punch Clean away any chips Install the punch and tighten the nut to cut the hole Deburr any...

Page 7: ...OLYTUBE TO DRAIN PORT ON RO SYSTEM BLUE 3 8 POLYTUBE PRODUCT OUTLET 5 Connect the tubing to the Faucet Push the Blue 3 8 Polytube into the 3 8 Quick Connect Fitting Push the Black 3 8 Polytube onto th...

Page 8: ...til it is fully pierced When you feel the Valve Handle firmly seated in the clockwise direction the copper tube is pierced and the valve is closed 2b To install on hard Steel or Brass Tubing supply li...

Page 9: ...and tighten them until the heads are about 5 8 from the wall RED BLACK YELLOW IN DRAIN OUT DRAIN RESTRICTOR 2 Locate the Red Feed Water Tubing Remove the red plug from the fitting labeled In on the ma...

Page 10: ...nd install prefilter O rings up toward manifold Insert a Housing O ring into the Housing groove press firmly in place Engage and firmly tighten the Housing hand tight only Remove the plugs labeled ACT...

Page 11: ...ood idea to resanitize the system and to change the prefilter and post filters B Changing Filters THIS R O SYSTEM CONTAINS FILTERS WHICH MUST BE REPLACED AT REGULAR INTERVALS TO MAINTAIN PROPER PERFOR...

Page 12: ...st 8 hours Discard the first three full tanks of water produced they will contain chlorine IN LINE ACTIVATED CARBON POST FILTER ASSEMBLY OUT IN In Line Activated Carbon Post Filter 3 8 Blue To Dispens...

Page 13: ...13 NOTES...

Page 14: ...14 NOTES...

Page 15: ...15 NOTES...

Page 16: ...eck The ASO Valve is malfunctioning Replace ASO Valve components Low pressure at the Dispensing Faucet In Line Activated Carbon Post Filter is plugged Replace Post Filter Air precharge in the Holding...

Page 17: ...r in the Holding Tank Clean flush and sanitize the system Replace the filters The Product Water and Drain Water lines are reversed Correct plumbing Dissolved gasses in the Feed Water Pretreat Feed Wat...

Page 18: ...18 MADE IN USA 15 Exploded View Parts List 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 18 17...

Page 19: ...S7028 Activated Carbon Prefilter 13 S3069 Housing O Ring 14 S7029 09 Housing 15 S2116 5 Drain Restrictor 50 GPD 189 lpd 16 S1764RS T F C RO Membrane 50 gpd 189 lpd 17 S1405 1 4 3 8 Fitting Wrench 18...

Page 20: ...harges You must also pay for shipping or travel charges to return the defective part s What Does This Warranty Not Cover This warranty does not cover the disposable sediment and carbon filters whose s...

Reviews: