8

FEED WATER SADDLE VALVE

 

Cold Water

Line

Saddle

Valve

Handle

Insert

Plastic

Ferrule

Red Tubing To

Manifold

Inlet

Compression

Nut

Tightening

Screw

Reversible

Back Plate

Figure 3 

B.  Feed Water Saddle Valve Installation 
  Decide on location. Do NOT connect to a 

hot water feed line. If you are not sure of the 

supply, run the hot water and feel the supply 

piping. Water over 100°F may cause permanent 

damage to the R.O. Membrane. (Refer to Fig. 3.)
1.  Shut off the water supply and drain the line.
2a. To install on (soft) Copper Tubing supply  

line:
•Turn the Handle of the Feed Water Saddle 

Valve counter clockwise (outward) until the 

lance does not protrude from the gasket. It 

may have to be pushed in. 

•Assemble the Feed Water Saddle Valve on 

the tubing.

– for 

3

/

8

" OD tubing use the back plate side 

with the small groove to prevent distortion 

of the tubing. 

– for larger tubing (up to 

5

/

8

" OD) use the 

large groove of the back plate. 

•Assemble and tighten the brass screw. 
•To pierce the tubing, turn the Valve Handle 

fully clockwise (inward). A small amount of 

water may escape from the outlet until it is 

fully pierced. 

•When you feel the Valve Handle firmly 

seated in the clockwise direction, the 

copper tube is pierced and the valve is 

closed.

2b. To install on (hard) Steel or Brass Tubing 

supply line. 
•The supply line should now be drained. Use 

a battery powered or properly grounded drill 

to avoid shock hazard. 

•Drill a 

3

/

16

" hole in the supply line; (do not 

drill through the opposite wall). 

•Turn the handle to expose the lance no 

more than 

3

/

16

" beyond the rubber gasket. 

•Place the body of the valve over the hole so 

that the lance fits into the hole. 

•Assemble and tighten the brass screw. 
•Turn the Valve Handle clockwise (inward) 

until firmly seated. The valve is closed. 

3.  With the Feed Water Saddle Valve closed, 

open the sink faucet and the water supply 

and allow the water to run for a few minutes 

to flush any debris caused by the installation. 
• Close the faucet and check the Feed Water 

Saddle Valve for leaks.

C.  Drain Clamp Installation 

3/8" DRAIN CLAMP ASSEMBLY

Drain Clamp

Front Plate

Drain Pipe

1/4" Nut

1/4" Screw

Drain Clamp

Back Plate

Black Drain Tubing

 

Figure 4

  The following are instructions for discharging 

into the sink drain pipe. (Refer to Fig. 1.)
1.  Position the Drain Clamp on the sink drain 

pipe above the drain trap. Allow room for 

drilling. Tighten securely. 

Summary of Contents for T.F.C.-400

Page 1: ...components critical for effective performance It is the user s responsibility to and the manufacturer strongly recommends that the user periodically test the product water to verify the system is per...

Page 2: ...8 C Drain Clamp Installation 8 D R O Manifold Assembly Installation 9 E Position the Drinking Water Holding Tank and Make the Final Hose Connections 10 F Start Up 10 SECTION IV OPERATION AND MAINTENAN...

Page 3: ...cess dissolved minerals are separated from the incoming water Feed Water to produce the product water the Permeate The excess minerals are rinsed to drain the Reject Water The membrane is a specially...

Page 4: ...king water holding tank mount holding tank on shelf or strap between floor joists shelf or straps not included activated carbon pREfilter housing Reverse osmosis membrane housing sediment prefilter ho...

Page 5: ...hours The production rate of a new Membrane can decrease by 10 per year or more depending upon the scaling and fouling tendencies of the Feed Water TABLE B RECOMMENDED OPERATING LIMITS FOR FEED WATER...

Page 6: ...ller drill as a pilot and then drill a diameter hole to accept the bolt of a 1 Greenlee Hole Punch 1 chassis punch Clean away any chips Install the punch and tighten the nut to cut the hole Deburr any...

Page 7: ...OLYTUBE TO DRAIN PORT ON RO SYSTEM BLUE 3 8 POLYTUBE PRODUCT OUTLET 5 Connect the tubing to the Faucet Push the Blue 3 8 Polytube into the 3 8 Quick Connect Fitting Push the Black 3 8 Polytube onto th...

Page 8: ...til it is fully pierced When you feel the Valve Handle firmly seated in the clockwise direction the copper tube is pierced and the valve is closed 2b To install on hard Steel or Brass Tubing supply li...

Page 9: ...and tighten them until the heads are about 5 8 from the wall RED BLACK YELLOW IN DRAIN OUT DRAIN RESTRICTOR 2 Locate the Red Feed Water Tubing Remove the red plug from the fitting labeled In on the ma...

Page 10: ...nd install prefilter O rings up toward manifold Insert a Housing O ring into the Housing groove press firmly in place Engage and firmly tighten the Housing hand tight only Remove the plugs labeled ACT...

Page 11: ...ood idea to resanitize the system and to change the prefilter and post filters B Changing Filters THIS R O SYSTEM CONTAINS FILTERS WHICH MUST BE REPLACED AT REGULAR INTERVALS TO MAINTAIN PROPER PERFOR...

Page 12: ...st 8 hours Discard the first three full tanks of water produced they will contain chlorine IN LINE ACTIVATED CARBON POST FILTER ASSEMBLY OUT IN In Line Activated Carbon Post Filter 3 8 Blue To Dispens...

Page 13: ...13 NOTES...

Page 14: ...14 NOTES...

Page 15: ...15 NOTES...

Page 16: ...eck The ASO Valve is malfunctioning Replace ASO Valve components Low pressure at the Dispensing Faucet In Line Activated Carbon Post Filter is plugged Replace Post Filter Air precharge in the Holding...

Page 17: ...r in the Holding Tank Clean flush and sanitize the system Replace the filters The Product Water and Drain Water lines are reversed Correct plumbing Dissolved gasses in the Feed Water Pretreat Feed Wat...

Page 18: ...18 MADE IN USA 15 Exploded View Parts List 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 18 17...

Page 19: ...S7028 Activated Carbon Prefilter 13 S3069 Housing O Ring 14 S7029 09 Housing 15 S2116 5 Drain Restrictor 50 GPD 189 lpd 16 S1764RS T F C RO Membrane 50 gpd 189 lpd 17 S1405 1 4 3 8 Fitting Wrench 18...

Page 20: ...harges You must also pay for shipping or travel charges to return the defective part s What Does This Warranty Not Cover This warranty does not cover the disposable sediment and carbon filters whose s...

Reviews: