X141-PT Pressure Transmitters
The Cla-Val Model X141-PT consists of a pressure transmitter installed with isolation valves mounted on
the main valve inlet and/or outlet. The rugged design provides resistance to vibration, shock, wide
temperature variations, RFI and other extreme environmental conditions.
Performance and reliability
are enhanced by the all-stainless steel welded measuring cell that eliminates the need for soft sealing
materials that may deteriorate over time.
The X141-PT pressure transmitter can be installed on
new or existing valves on the valve inlet and/or
outlet. The 141-PT transmitters can be paired with
Cla-Val Model X141 Pressure Gauges for both local
and remote valve pressure information. Default
configuration for the XP2F package includes 2
pressure transmitters, one for upstream pressure
and one for downstream pressure. The transmitter
requires a supply voltage of 8-30 VDC. This
transmitter will output an industry standard 4-20 mA
signal when using the default 2-wire setup. The
X141-PT will provide an accuracy of ±0.5% of the
span.
There is no field calibration or internal setup
required for the X141-PT. If needed, zero-point
calibration can be done on whatever controller is being used. For wiring examples, refer to
Figure 3.1