Compact flow rate controller RAPIFLOW
FCM
Series
IO-Link
●
For air, nitrogen, argon, oxygen, city gas, methane, propane (flow
rate range: 0.5 to 100 L/min)
●
For hydrogen, helium (flow rate range: 0 to 20 L/min)
■
FCM Series for air, nitrogen, argon, oxygen, city gas, methane, propane
Specifications
Model No.
Descriptions
FCM-[*1][*2]-[*3]C
Valve drive method
Proportional solenoid valve - When not energized: Closed
Full scale flow rat
e
AI (Air, nitrogen) AR (Argon) O2 (Oxygen) LN (City gas) C1 (Methane) C3 (Propane)
Flow rate range
*1
*1
Standard
9500 500 mL/min
●
●
●
●
●
●
0001 1 L/min
●
●
●
●
●
●
0002 2 L/min
●
●
●
●
●
●
0005 5 L/min
●
●
●
●
●
●
0010 10 L/min
●
●
●
●
●
●
0020 20 L/min
●
●
0050 50 L/min
●
●
0100 100 L/min (Resin type only)
●
Low dif
ferential p
ressure type
(Stain
less steel only)
L9500 500 mL/min
●
●
●
●
●
L0001 1 L/min
●
●
●
●
●
L0002 2 L/min
●
●
●
●
●
L0005 5 L/min
●
●
●
●
●
L0010 10 L/min
●
●
●
●
●
Applica
ble fluids
*2
*2
AI
Compressed air, nitrogen
●
AR
Argon
●
O2
Oxygen (Oil-prohibited)
●
LN
City gas (13A)
*3
●
C1
Methane (CH4 100%)
●
C3
Propane (C3H8 100%)
●
Port size, body
material
*3
H6
ø6 push-in, resin (excluding 50, 100 L/min)
●
H8
ø8 push-in, resin
●
8A
RC1/4, stainless steel
●
●
●
●
●
●
UF
9/16-18UNF, stainless steel
●
●
●
●
●
●
Control
Control range
3 to 100% F.S.
Response
time
*1
9500 to 0020
Within 0.5 sec. to setting ±5% F.S. (TYP.)
0050 to 0100
Within 1 sec. to setting ±5% F.S. (TYP.)
Accuracy
Within ±3% F.S.
Repeatability
Within ±1% F.S.
Temperature characteristics
Within ±0.2% F.S./ °C (base temperature 25 °C)
Pressure characteristics
Within ±1% F.S. per 98 kPa (standard differential pressure reference)
Pressure
Standard differential pressure *4
Refer to the separate table
Working pressure differential *5
Refer to the separate table
Max. working pressure
*5
Refer to the separate table
Proof
pressure *2
H6/H8
490 kPa
8A/UF
980 kPa
Operating ambient temperature,
operating ambient humidity
0 to 50 °C, 90% RH or less (non-condensing)
I/O
Input signal
C
IO-Link
Flow rate
display
Display method
7-segment LED 3-digit, indicator accuracy: control accuracy ±1 digit
Display range, display resolution
Refer to the separate table
Integrating functions
Refer to the separate table
Power
supply
Power supply voltage
24 VDC ± 10% (stabilized power supply with ripple rate 1% or less)
Current consumption *6
200 mA or less (Port type A)
Mounting orientation
Unrestricted in vertical/horizontal direction
Wetted section
materials
*3
H6/H8
Polyamid
e resin, fluoro rubb
er, stainless steel, alumina, semiconductor silicon, soldering
8A/UF
Stainless st
eel, fluoro rubber,
alumina, semiconductor silicon, soldering
Weight
*3
H6/H8
Approx. 200 g
8A/UF
Approx. 480 g
Degree of protection
IEC standards IP40 or equivalent
Protection circuit
*7
Power supply reverse connection protection
EMC Directive
EN55011, EN61000-6-2, EN61000-4-2/3/4/6/8