FCM
Series
Communication specifications
Communication specifications
* Refer to the SM-A19060 instruction manual for para
meter configuration.
* The IO-Link sett
ing file (IODD) can
be downloaded from the CKD website (https://www.ckd.co.jp).
Descriptions
Details
Communication protocol
IO-Link
Communication protocol version
1.1 V
Transmission bit rate
COM3 (230.4 kbps)
Port type
A
Process data length (input)
10 byte
Process data length (output)
4 byte
Device ID
Product ID
Remarks
0x216001
FCM-9500-C
500 mL/min Range
0x216002
FCM-0001-C
1 L/min Range
0x216003
FCM-0002-C
2 L/min Range
0x216004
FCM-0005-C
5 L/min Range
0x216005
FCM-0010-C
10 L/min Range
0x216006
FCM-0020-C
20 L/min Range
0x216007
FCM-0050-C
50 L/min Range
0x216008
FCM-0100-C
100 L/min Range
Model No.
Instantaneous flow rate
Accumulated flow
Display range
Display value
ProcessData
output value
Accumulated
display range
Display value
FCM-(L)9500*-*C
0 to 500.0 mL/min
0 to 500
0 to 5000
0 to 999999 mL
0 to 999999
FCM-(L)0001*-*C
0.00 to 1.000 L/min
0 to 1.00
0 to 1000
0 to 9999.99 L
FCM-(L)0002*-*C
0.00 to 2.000 L/min
0 to 2.00
0 to 2000
FCM-(L)0005*-*C
0.00 to 5.000 L/min
0 to 5.00
0 to 5000
FCM-(L)0010*-*C
0.0 to 10.00 L/min
0 to 10.0
0 to 1000
0 to 99999.9 L
FCM-0020*-*C
0.0 to 20.00 L/min
0 to 20.0
0 to 2000
FCM-0050*-*C
0.0 to 50.00 L/min
0 to 50.0
0 to 5000
FCM-0100*-*C
0 to 100.0 L/min
0 to 100
0 to 1000
0 to 999999 L
Descriptions
Details
Min. cycle time
2 ms
Data storage
1 kbyte
SIO mode support
No
Device ID
Refer to table below
Vendor ID
855 (decimal)/357 (hexadecimal)
■
Communication specifications
General
■
Parameter
Device ID
Table 1 Flow rate range per model
14
Summary of Contents for FCM-0001 AI
Page 29: ...ME M O MEMO 24 ...